17.2
Reset parameters to default
Parameter
Address
Name / setting range / [default setting]
Info
0x2022:001
Device commands: Load default settings
1 ≡ reset all parameters in the RAM memory of the inverter to the
default setting that is stored in the inverter firmware.
•
All parameter changes made by the user are lost during this process!
•
It may take some seconds to execute the task. When the task has
been executed successfully, the value 0 is shown.
•
Loading parameters has a direct effect on the cyclic communication:
The data exchange for control is interrupted and a communication
error is generated.
0 Off / ready
Only status feedback
1 On / start
Execute device command
2 In progress
Only status feedback
3 Action cancelled
4 No access
5 No access (Inverter disabled)
0x2022:039
Device commands: Load TA default settings
0 Off / ready
Only status feedback
1 On / start
Execute device command
2 In progress
Only status feedback
3 Action cancelled
4 No access
5 No access (Inverter disabled)
Device functions
Reset parameters to default
378
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......