Configure position control
This operating mode provides a fast position follower with speed, torque and feed force feed-
forward control.
Typical applications for positioning are, for instance, transport facilities, feed drives and dos-
ing systems.
Preconditions
A positioning control is parameterised in the servo control types to be set.
Configure one of these motor control types:
•
= 1:
Servo control for synchronous motor (SC-PSM)
•
= 2:
Servo control for asynchronous motor (SC-ASM)
Further conditions are:
•
The correct entry of the
•
The parameter setting of the motor control in chapter
Configure position control
154