5.4
Motor data
The term "motor data" comprises all parameters only depending on the motor and only char-
acterising the electrical behaviour of the motor. Motor data are independent of the applica-
tion in which the inverter and the motor are used.
Preconditions
The equivalent circuit data ("Settings" tab, path: "Basic setting\motor", parameterisation dia-
log "Derived motor properties and equivalent circuit") apply to a motor in star connection. In
case of a motor in delta connection, the delta values must be converted into equivalent star
values.
Possible settings
If a Lenze motor is connected to the inverter, you can select the motor in the engineering tool
from the "motor catalogue".
•
For details see chapter "
Select motor from motor catalogue
Otherwise the motor data must be set manually (for details see chapter "
Parameter
Address
Name / setting range / [default setting]
Info
0x2C08
Method for setting motor parameters
Representation of the method selected for setting the motor parame-
ters. (Is used by the engineering tools.)
1 Select from catalogue (Lenze motors)
2 Enter motor nameplate data (other motors)
3 Manual input (other motors)
4 Identification run (all motors)
Basic setting
Motor data
38
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......