17.3
Saving/loading the parameter settings
If parameter settings of the inverter are changed, these changes at first are only made in the
RAM memory of the inverter. In order to save the parameter settings with mains failure pro-
tection, the inverter is provided with the corresponding device command in the parameter.
Parameter
Address
Name / setting range / [default setting]
Info
0x2022:003
Device commands: Save user data
1 = save current parameter settings in the user memory of the memory
module with mains failure protection.
•
It may take some seconds to execute the task. When the device com-
mand has been executed successfully, the value 0 is shown.
•
Do not switch off the supply voltage during the saving process and do
not unplug the memory module from the inverter!
•
When the inverter is switched on, all parameters are automatically
loaded from the user memory of the memory module to the RAM
memory of the inverter.
0 Off / ready
Only status feedback
1 On / start
Execute device command
2 In progress
Only status feedback
3 Action cancelled
4 No access
5 No access (Inverter disabled)
101 No SD card connected
102 SD card is write protected
103 SD card is full
0x2022:040
Device commands: Parameter-Backup
•
Setting can only be changed if the inverter is inhibi-
ted.
0 Off / ready
Only status feedback
1 On / start
Execute device command
2 In progress
Only status feedback
3 Action cancelled
4 No access
5 No access (Inverter disabled)
20 20%
40 40%
60 60%
80 80%
100 100%
101 No SD card connected
102 SD card is write protected
103 SD card is full
0x2022:043
Device commands: Restore
•
Setting can only be changed if the inverter is inhibi-
ted.
0 Off / ready
Only status feedback
1 On / start
Execute device command
2 In progress
Only status feedback
3 Action cancelled
4 No access
5 No access (Inverter disabled)
20 20%
40 40%
60 60%
80 80%
100 100%
101 No SD card connected
Device functions
Saving/loading the parameter settings
379
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......