Address
Name / setting range / [default setting]
Info
0x500C:030
Traversing range
•
Setting can only be changed if the inverter is inhibi-
ted.
Specification of the traversing range for the virtual master axis.
•
0: Linearly limited traversing range (spindle drive).
•
1: Unlimited traversing range (turntable). The cycle length must also
be specified here.
0 Modulo
1 Limited
0x500C:031
Cycle length
0.0001 ... [360.0000] ... 214748.3647
•
Setting can only be changed if the inverter is inhibi-
ted.
The cycle length for an unlimited traversing range defines at which posi-
tion the measuring system is repeated (position return to 0).
0x500C:045
Max. velocity
0.0000 ... [0.0000] ... 214748.3647
0x500C:046
Max. acceleration
0.00 ... [0.00] ... 21474836.47
0x500C:047
Max. jerk
0.00 ... [0.00] ... 21474836.47
0x500C:048
Application quick stop - deceleration
0.01 ... [3600.00] ... 21474836.47
0x500C:049
Application quick stop - jerk
0.00 ... [0.00] ... 21474836.47
0x500C:050
Enable software limit switches
false Inactive
true Active
0x500C:051
Software limit switch positive
-214748.3648 ... [0.0000] ... 214748.3647
0x500C:052
Software limit switch negative
-214748.3648 ... [0.0000] ... 214748.3647
0x500C:053
Action after "software limit switch reached"
0 Stop after software limit switch
1 Stop at software limit switch
0x500C:105
Action after "software limit switch reached"
19 Fault > Application quick stop > Quick stop
21
0x500C:106
Response to "profile limit reached"
0 No Response
2 Warning
19 Fault > Application quick stop > Quick stop
21
0x500C:150
SLS1
0.0000 ... [0.0000] ... 214748.3647
0x500C:151
SLS1 - deceleration time
0.000 ... [0.000] ... 2147483.647 s
0x500C:152
SLS2
0.0000 ... [0.0000] ... 214748.3647
0x500C:153
SLS2 - deceleration time
0.000 ... [0.000] ... 2147483.647 s
0x500C:154
SLS3
0.0000 ... [0.0000] ... 214748.3647
0x500C:155
SLS3 - deceleration time
0.000 ... [0.000] ... 2147483.647 s
0x500C:156
SLS4
0.0000 ... [0.0000] ... 214748.3647
0x500C:157
SLS4 - deceleration time
0.000 ... [0.000] ... 2147483.647 s
Configuring the "Sync and Correction" TA
Master value sources
Virtual master
109
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......