Address
Designation
Default setting
Data type
Factor A
M
Device utilisation ixt: Power unit error threshold
x % (Read only)
U16
1
X
Device utilisation ixt: Device actual utilisation
x % (Read only)
U16
1
X
●
Device utilisation ixt: Device warning threshold
95 %
U16
1
-
Device utilisation ixt: Device error threshold
x % (Read only)
U16
1
X
Device utilisation ixt: Actual total utilisation
x % (Read only)
U16
1
X
●
Device utilisation ixt: Total utilisation warning
threshold
95 %
U16
1
-
Device utilisation ixt: Total utilisation error threshold x % (Read only)
U16
1
X
Overspeed monitoring: Threshold
8000 rpm
U16
1
-
Overspeed monitoring: Response
Fault > CiA402 [1]
U8
-
Motor phase failure detection: Response - Motor
phase 1
No response [0]
U8
-
Motor phase failure detection: Current threshold
5.0 %
U8
10
-
Motor phase failure detection: Voltage threshold
10.0 V
U16
10
-
Motor phase failure detection: Response - Motor
phase 2
No response [0]
U8
-
Overcurrent monitoring: Threshold
5.4 A
U16
10
-
Overcurrent monitoring: Response
Fault > CiA402 [1]
U8
-
PTC temperature sensor monitoring: Error response Fault > CiA402 [1]
U8
-
Motor temperature monitoring: Temperature sensor
type
PT1000 [5]
U8
-
Motor temperature monitoring: Response
Fault > CiA402 [1]
U8
-
Motor temperature monitoring: Warning threshold 145.0 °C
I16
10
-
Motor temperature monitoring: Error threshold
155.0 °C
I16
10
-
Motor temperature monitoring: Actual motor tem-
perature
x.x °C (Read only)
I16
10
X
●
Motor temperature monitoring: Spec. characteristic
temperature grid point 1
25.0 °C
I16
10
-
Motor temperature monitoring: Spec. characteristic
temperature grid point 2
150.0 °C
I16
10
-
Motor temperature monitoring: Spec. characteristic
resistance grid point 1
1000 Ω
I16
1
-
Motor temperature monitoring: Spec. characteristic
resistance grid point 2
2225 Ω
I16
1
-
Motor temperature monitoring: Temperature sensor
feedback type
KTY83-110 [0]
U8
-
Motor temperature monitoring: Motor temperature
(Motor encoder)
x.x °C (Read only)
I16
10
X
●
Motor temperature monitoring: Motor temperature
(load encoder)
x.x °C (Read only)
I16
10
X
●
Thermisches Modell Motorauslastung (i²xt): Motor
utilisation (i²xt)
60 s
U16
1
-
Thermisches Modell Motorauslastung (i²xt): Ther-
mal time constant - laminations
852 s
U16
1
-
Thermisches Modell Motorauslastung (i²xt): Wind-
ing influence
27 %
U8
1
-
Thermisches Modell Motorauslastung (i²xt): Starting
value
0 %
U16
1
-
Motor utilisation (i²xt) - specific characteristic: x1 =
n01/nN (n01 ~ 0)
0 %
U16
1
-
Motor utilisation (i²xt) - specific characteristic: y1 =
i01/iN (x1)
100 %
U16
1
-
Motor utilisation (i²xt) - specific characteristic: x2 =
n02/nN (n02 = limit reduced cooling)
0 %
U16
1
-
Motor utilisation (i²xt) - specific characteristic: y2 =
i02/iN (x2)
100 %
U16
1
-
Motor utilisation (i²xt) - specific characteristic: x3 =
n03/nN (n03 = rated speed)
100 %
U16
1
-
* Default setting depending on the size.
Appendix
Parameter attribute list
483
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......