Homing mode 19: CwRpCcwRn
0
①
②
Fig. 13: Sequence representation of case 1 and case 2
A
Reference switch
Sequence of case
①
:
The axis has not yet activated the reference switch:
1
.
The machine part moves in positive direction with profile data set 1.
2
.
Machine part reverses with positive edge of the reference switch (A) and changes to pro-
file data set 2.
3
.
The negative edge of the reference switch (A) sets the reference.
4
.
Further actions can be selected:
•
Drive stops (default setting).
•
Relative positioning by a set target position.
•
Absolute positioning to a set target position.
Sequence of case
②
:
The axis has already activated the reference switch:
1
.
The machine part moves in negative direction with profile data set 2.
2
.
The negative edge of the reference switch (A) sets the reference.
3
.
Further actions can be selected:
•
Drive stops (default setting).
•
Relative positioning by a set target position.
•
Absolute positioning to a set target position.