8
Start, stop and rotating direction commands
8.1
Control selection
Parameter
Address
Name / setting range / [default setting]
Info
0x2824
Control selection
•
Setting can only be changed if the inverter is inhibi-
ted.
Selection of the type of inverter control.
0 Flexible I/O configuration
This selection enables a flexible assignment of the start, stop, and rotat-
ing direction commands with digital signal sources.
•
Digital signal sources can be digital inputs, network and keypad.
•
The I/O configuration is made via the parameters 0x2631:xx (P400.xx).
1 Keypad
This selection enables the motor to be started exclusively via the start
key of the keypad. Other signal sources for starting the motor are
ignored.
Start motor
Stop motor
Note!
•
The functions "Enable inverter" and "Run" must be set to TRUE to
start the motor.
•
If jog operation is active, the motor cannot be stopped via the
keypad key.