Address
Name / setting range / [default setting]
Info
0x2C44:006
Motor encoder identification (Resolver): Identification
status
•
Read only
Display of the resolver identification status.
Bit 0 Identification activated
TRUE if:
•
Identification has been started.
•
Controller enable is active.
FALSE if:
•
Identification has been aborted or completed successfully.
•
A timeout error is active.
•
The 24V supply has been switched on and default settings are loaded.
Bit 1 Constant speed detected
TRUE if:
•
A constant motor speed has been detected.
FALSE if:
•
Identification has been aborted or completed successfully.
•
A timeout error is active.
•
The 24V supply has been switched on and default settings are loaded.
Bit 2 Identification is running
TRUE if:
•
Identification is running.
FALSE if:
•
The motor speed has fallen below the minimum speed of 500 rpm.
•
The identification process has been aborted temporarily and is on
standby.
Bit 3 Identification successful
TRUE if:
•
Identification has been completed successfully.
FALSE if:
•
The identification is not completed yet after default settings were loa-
ded.
Bit 4 Identification failed
TRUE if:
•
A timeout error has occurred.
FALSE if:
•
Identification has been completed successfully.
12.1.3
Encoder settings
In general, an encoder is a measuring system which serves to detect the velocity/speed and
the position of a kinematics or motor.
Details
If a resolver variant is to be plugged into the respective slot of the inverter as a
feedback system, the parameters in this section have no function.
Parameter
Address
Name / setting range / [default setting]
Info
0x2C40
Motor encoder type
•
Setting can only be changed if the inverter is inhibi-
ted.
Selection of the encoder type.
1 SinCos encoder
2 Hiperface absolute value encoder
5 SSI encoder
0x2C42:001
Encoder settings: Increments/revolution
1 ... [1024] ... 131072
•
Setting can only be changed if the inverter is inhibi-
ted.
Setting of the encoder number of increments per revolution (according
to manufacturer data/encoder data sheet).
Configuring the feedback system
Configure feedback system for motor control
Resolver settings
206
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......