6.4
System bus communication
The system bus serves to transfer cyclic-synchronous master values. For the transfer, 8 input
words and 8 output words are available, with a data width of 32 bits each. The assignment of
the double words is shown in the figure "Assignment of system bus input/output".
FB
FB
TM
Control module
System bus out parameter
Cycle length (0x5021:150)
Position (0x5021:151)
Velocity (0x5021:152)
Acceleration (0x5021:153)
Torque (0x5021:154
Time stamp TP (0x5021:155)
TA specific (0x5021:XXX)
TA specific (0x5021:XXX)
Cycle length (0x5021:160)
Position (0x5021:161)
Velocity (0x5021:162)
Acceleration (0x5021:163)
Torque (0x5021:164
Time stamp TP (0x5021:165)
TA specific (0x5021:XXX)
TA specific (0x5021:XXX)
System bus in parameter
System bus inputs
System bus outputs
Fig. 23: Assignment of system bus inputs/outputs
Information on network configuration
6.4.1
Inputs
The following parameters are available for the diagnostics of the system bus input values:
Parameter
Address
Name / setting range / [default setting]
Info
0x5021:150
System bus diagnostics: Cycle length (input value)
•
Read only
Cycle length of the master axis
0x5021:151
System bus diagnostics: Position (input value)
•
Read only
Master position value
0x5021:152
System bus diagnostics: Velocity (input value)
•
Read only
Speed conductivity
0x5021:153
System bus diagnostics: Acceleration (input value)
•
Read only
Acceleration conductivity
0x5021:154
System bus diagnostics: Torque (input value)
•
Read only: x.xx Nm
Torque of the master axis
0x5021:155
System bus diagnostics: Time stamp (input value)
•
Read only: x ns
Time stamp of the master axis
0x5021:156
System bus diagnostics: Input data word 6
•
Read only
This system bus input word is currently not used, but can be connected
in the technology application by the user.
0x5021:157
System bus diagnostics: Input data word 7
•
Read only
6.4.2
Outputs
The following parameters are available for the diagnostics of the system bus output values:
Parameter
Address
Name / setting range / [default setting]
Info
0x5021:160
System bus diagnostics: Cycle length (output value)
•
Read only
Cycle length of the source set via Master value output of system bus
0x5020:001.
0x5021:161
System bus diagnostics: Position (output value)
•
Read only
Master position value of the source set via Master value output of sys-
tem bus 0x5020:001.
0x5021:162
System bus diagnostics: Velocity (output value)
•
Read only
Master speed value of the source set via Master value output of system
bus 0x5020:001.
0x5021:163
System bus diagnostics: Acceleration (output value)
•
Read only
Master acceleration value of the source set via Master value output of
system bus 0x5020:001.
0x5021:164
System bus diagnostics: Torque (output value)
•
Read only: x.xx Nm
Torque of the master axis of the source set via Master value output of
system bus 0x5020:001.
0x5021:165
System bus diagnostics: Time stamp (output value)
•
Read only: x ns
Time stamp of the touchprobe source in ns selected via source TP1
.
Technology application (TA) basic settings
System bus communication
Inputs
82
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......