Address
Name / setting range / [default setting]
Info
0x2D01:003
Touch probe (TP) time stamp: Touch probe 2-rising
edge time stamp
•
Read only: x ns
Display of the time stamp of the rising edge for touch probe 2.
0x2D01:004
Touch probe (TP) time stamp: Touch probe 2-falling
edge time stamp
•
Read only: x ns
Display of the time stamp of the falling edge for touch probe 2.
0x2D01:005
Touch probe (TP) time stamp: Touch probe 3-rising
edge time stamp
•
Read only: x ns
Display of the time stamp of the rising edge for touch probe 3.
0x2D01:006
Touch probe (TP) time stamp: Touch probe 3-falling
edge time stamp
•
Read only: x ns
Display of the time stamp of the falling edge for touch probe 3.
0x2D01:007
Touch probe (TP) time stamp: Touch probe 4-rising
edge time stamp
•
Read only: x ns
Display of the time stamp of the rising edge for touch probe 4.
0x2D01:008
Touch probe (TP) time stamp: Touch probe 4-falling
edge time stamp
•
Read only: x ns
Display of the time stamp of the falling edge for touch probe 4.
0x60BA
Touch probe pos1 pos value
•
Read only: x pos. unit
Touch probe position 1 detected with rising edge.
0x60BB
Touch probe pos1 neg value
•
Read only: x pos. unit
Touch probe position 1 detected with falling edge.
0x60BC
Touch probe pos2 pos value
•
Read only: x pos. unit
Touch probe position 2 detected with rising edge.
0x60BD
Touch probe pos2 neg value
•
Read only: x pos. unit
Touch probe position 2 detected with falling edge.
9.7
Setpoint diagnostics
The following parameters provide information on the setpoints set for position control.
Parameter
Address
Name / setting range / [default setting]
Info
0x6062
Position demand value
•
Read only: x pos. unit
Display of the interpolated setpoint position for the position control.
0x6063
Position actual internal value
•
Read only: x incr.
Display of the current position in the internal unit.
0x60FC
Position demand internal value
•
Read only: x incr.
Display of the interpolated setpoint position for the position control in
the internal unit.
0x60FA
Control effort
•
Read only: rpm
Display of the actuating signal (setpoint speed) of the position controller.
Configure position control
Setpoint diagnostics
170
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......