Address
Name / setting range / [default setting]
Info
0x500C:162
Deactivate safety interface
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
Bit 1 Ignore SS1 request
Bit 2 Ignore SS2 request
Bit 3 Ignore SLS1 - SLS4 request
Bit 4 Ignore SDI request
0x500C:163
Limiter call
•
Read only
Bit 0 STO active
Bit 1 SS1 active
Bit 2 SS2 active
Bit 4 SLS1 active
Bit 5 SLS2 active
Bit 6 SLS3 active
Bit 7 SLS4 active
Bit 8 SDIpos active
Bit 9 SDIneg active
0x500C:181
Manual jog velocity
0.0000 ... [360.0000] ... 214748.3647
0x500C:182
Manual jog acceleration
0.00 ... [720.00] ... 21474836.47
0x500C:183
Manual jog deceleration
0.00 ... [1440.00] ... 21474836.47
0x500C:184
Manual jog jerk
0.00 ... [0.00] ... 21474836.47
0x500C:186
Deceleration of Halt
0.00 ... [1800.00] ... 21474836.47
0x500C:187
Jerk of Halt
0.00 ... [0.00] ... 21474836.47
Configuring the "Sync and Correction" TA
Master value sources
Virtual master
110