12.2.2
Resolver settings
Resolvers with a number of pole pairs > 1 are not absolute value encoders.
Bit 10 in (Lenze status word 2) therefore remains set to "0".
The "distinguishable revolutions" specification in
is also set to "0".
Parameter
Address
Name / setting range / [default setting]
Info
0x2822:029
Axis commands: Get load encoder/master encoder
characteristic (resolver)
Definition of the resolver characteristic for application feedback.
0 Off / ready
Only status feedback
1 On / start
Execute device command
2 In progress
Only status feedback
3 Action cancelled
4 No access
5 No access (Inverter disabled)
0x2C53
Load encoder/master encoder resolver number of
pole pairs
1 ... [1] ... 1
•
Setting can only be changed if the inverter is inhibi-
ted.
Setting of the number of pole pairs.
Configuring the feedback system
Second feedback system for the techology application
Resolver settings
214