4
Commissioning
The purpose of commissioning is to adapt the inverter as part of a machine with a variable-
speed drive system to its drive task.
4.1
Important notes
DANGER!
Incorrect wiring can cause unexpected states during the commissioning phase.
Possible consequences: death, severe injuries or damage to property
Ensure the following before switching on the mains voltage:
▶
Wiring must be complete and correct.
▶
Wiring must be free of short circuits and earth faults.
▶
The motor circuit configuration (star/delta) must be adapted to the inverter output voltage.
▶
The motor must be connected in-phase (direction of rotation).
▶
The "emergency off" function of the overall system must operate correctly.
DANGER!
Incorrect settings during commissioning may cause unexpected and dangerous motor and sys-
tem movements.
Possible consequences: death, severe injuries or damage to property
▶
Clear hazardous area.
▶
Observe safety instructions and safety clearances.
Commissioning
Important notes
27
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......