Address
Name / setting range / [default setting]
Info
0x2C5A:007
Protokoll-Parameter Lastgeber/Leitgeber (SSI): Start-
bit Datenpaket 3
0 ... [0] ... 30
•
Setting can only be changed if the inverter is inhibi-
ted.
Indicates the position in the telegram where data packet 3 begins.
0x2C5A:008
Protokoll-Parameter Lastgeber/Leitgeber (SSI): Länge
Positionsdaten
0 ... [25] ... 30
•
Setting can only be changed if the inverter is inhibi-
ted.
SSI position data length
0x2C5A:009
Protokoll-Parameter Lastgeber/Leitgeber (SSI): Länge
Datenpaket 1
0 ... [0] ... 30
•
Setting can only be changed if the inverter is inhibi-
ted.
Length of data packet 1.
0x2C5A:010
Protokoll-Parameter Lastgeber/Leitgeber (SSI): Länge
Datenpaket 2
0 ... [0] ... 30
•
Setting can only be changed if the inverter is inhibi-
ted.
Length of data packet 2.
0x2C5A:011
Protokoll-Parameter Lastgeber/Leitgeber (SSI): Länge
Datenpaket 3
0 ... [0] ... 30
•
Setting can only be changed if the inverter is inhibi-
ted.
Length of data packet 3.
0x2C5A:012
Protokoll-Parameter Lastgeber/Leitgeber (SSI): Codier-
ung Positionsdaten
•
Setting can only be changed if the inverter is inhibi-
ted.
Coding of position data word (read only).
If a value of "0" is set for the position data length in
the value displayed for this parameter is also "0".
0 Binär
1 Gray
0x2C5A:013
Protokoll-Parameter Lastgeber/Leitgeber (SSI): Codier-
ung Datenpaket 1
•
Setting can only be changed if the inverter is inhibi-
ted.
Coding of data packet 1
0 Binär
1 Gray
0x2C5A:014
Protokoll-Parameter Lastgeber/Leitgeber (SSI): Codier-
ung Datenpaket 2
•
Setting can only be changed if the inverter is inhibi-
ted.
Coding of data packet 2
0 Binär
1 Gray
0x2C5A:015
Protokoll-Parameter Lastgeber/Leitgeber (SSI): Codier-
ung Datenpaket 3
•
Setting can only be changed if the inverter is inhibi-
ted.
Coding of data packet 3
0 Binär
1 Gray
0x2C5A:016
Protokoll-Parameter Lastgeber/Leitgeber (SSI): Roh-
daten Position
•
Read only
Raw value of position data word (read only).
If a value of "0" is set for the position data length in
the value displayed for this parameter is also "0".
0x2C5A:017
Protokoll-Parameter Lastgeber/Leitgeber (SSI): Roh-
daten Datenpaket 1
•
Read only
Raw value of data packet 1 (read only).
If a value of "0" is set for the data packet length 1 in
, then
the value displayed for this parameter is also "0".
0x2C5A:018
Protokoll-Parameter Lastgeber/Leitgeber (SSI): Roh-
daten Datenpaket 2
•
Read only
Raw value of data packet 2 (read only).
If a value of "0" is set for the data packet length 2 in
, then
the value displayed for this parameter is also "0".
0x2C5A:019
Protokoll-Parameter Lastgeber/Leitgeber (SSI): Roh-
daten Datenpaket 3
•
Read only
Raw value of data packet 3 (read only).
If a value of "0" is set for the data packet length 3 in
, then
the value displayed for this parameter is also "0".
Configuring the feedback system
Second feedback system for the techology application
Encoder settings
221
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......