v
t
Source TP 2
(0x5020:012)
v
t
v
max
Mark window size tool (0x5041:126)
Mark window offset tool (0x5041:127)
Max missed marks tool (0x5041:128)
Sensor distance
(0x5041:120)
-
Sensor set position
(0x5042:140)
+
Tool Sensor act position
(0x5042:141)
v
t
v
max
Max positive correction tool (0x5041:122)
Max negative correction tool (0x5041:123)
DI 1
DI 2
DI 3
DI 4
TP calculation
Mark window
Mark stack
Upper correction position tool (0x5041:124)
Lower correction position tool (0x5041:125)
SetPosition
relative
Tool Correction
Tool correction
(0x5041:120)
Actual tool error
(0x5042:142)
Actual tool error limited
(0x5042:143)
Fig. 65: Tool correction partial signal flow
Relevant parameters of other functions
Address
Designation
Default setting
Setting range
Cycle length
360.0000
0.0001 ... 214748.3647
Deceleration of Halt
1800.00
0.00 ... 21474836.47
TP1 source
Digital input 1, positive edge [1]
Selection list
Master value source
System bus [0]
Selection list
System bus diagnostics: Position (input value)
- (Read only)
Mark distance
360.0000
0.0000 ... 214748.3647
Max. positive correction
45.0000
0.0000 ... 214748.3647
Max. negative correction
45.0000
0.0000 ... 214748.3647
Reference measuring system of correction window
Corrected master position [1]
Selection list
Upper correction position
350.0000
0.0000 ... 214748.3647
Lower correction position
200.0000
0.0000 ... 214748.3647
Mark window size
40.0000
0.0000 ... 214748.3647
Mark window offset
0.0000
0.0000 ... 214748.3647
Max. number of missed marks
20
0 ... 4294967295
Gearbox factor correction gain
0.1000
0.0000 ... 214748.3647
Max. gearbox factor correction
10.0000
0.0000 ... 214748.3647
Sensor set position
- (Read only)
Actual mark position
- (Read only)
Actual mark error
- (Read only)
Actual limited mark error
- (Read only)
Actual gearbox factor
- (Read only)
Corrected set position
- (Read only)
Corrected set velocity
- (Read only)
Set position of selected master value
- (Read only)
Set velocity of selected master value
- (Read only)
Virtual master start position
0.0000
0.0000 ... 214748.3647
Virtual master set position
0.0000
0.0000 ... 214748.3647
Virtual master acceleration
100000.00
0.00 ... 21474836.47
Configuring the "Sync and Correction" TA
Signal flow
Master value selection and master value correction
150
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......