Address
Name / setting range / [default setting]
Info
0x5045:110
Virtual master status signals
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
Bit 0
Bit 1
Bit 2
Bit 3 Fault
Bit 4
Bit 5
Bit 6 Manual jog active
Manual operation is activated.
Bit 7 Warning
The warning is activated.
Bit 8 Halt active
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Bit 16
Bit 17
Bit 18
Bit 19
Bit 20
Bit 21
Bit 22
Bit 23
Bit 24
Bit 25 Busy
The virtual master is activated.
Bit 26 Taget reached
The axis has reached the target position and is at standstill.
Bit 27 Synchronized
Bit 28 Synchronization active
Bit 29
Bit 30
Bit 31 External master values deactivated
The external master value is deactivated in the system bus in the appli-
cation feedback (B).
0x5045:111
Actual position
-214748.3648 ... [0.0000] ... 214748.3647
The setpoint position is specified in [unit]. The setpoint position is
resolved with 4 decimal places.
0x5045:112
Actual velocity
-214748.3648 ... [0.0000] ... 214748.3647
The setpoint velocity is specified in [units/s]. The setpoint velocity is
resolved with 4 decimal places.
0x5045:113
Actual acceleration
-21474836.48 ... [0.00] ... 21474836.47
The current position is specified in [unit]. The current position is resolved
with 4 decimal places.
0x5045:114
Error code
0 ... [0] ... 4294967295
The current error number is displayed in the word.
0x5045:115
Cycle length
-214748.3648 ... [0.0000] ... 214748.3647
The current position is specified in [unit]. The current position is resolved
with 4 decimal places.
0x5046:001
Virtual master start position
0.0000 ... [0.0000] ... 214748.3647
0x5046:002
Virtual master set position
0.0000 ... [0.0000] ... 214748.3647
0x5046:003
Virtual master acceleration
0.00 ... [100000.00] ... 21474836.47
0x5046:004
Virtual master deceleration
0.00 ... [100000.00] ... 21474836.47
Configuring the "Sync and Correction" TA
Master value sources
Virtual master
107
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......