10.4
Process input data (CiA 402 objects)
Parameter
Address
Name / setting range / [default setting]
Info
0x2830
Inverter control word
0x0000 ... [0x0000] ... 0xFFFF
The control word serves to influence the control functions.
Bit 0 Flying restart completed
This bit enables the control to report the acceptance of the recorded
speed to the "flying restart" function. Thus, the flying restart process is
completed.
Bit 1 Block flying restart
TRUE: the flying restart process is blocked.
Bit 4 Set load value
TRUE: set load value.
Bit 5 Select new actual position
TRUE: define new actual position.
•
Setting/shifting of Position actual value (
) to Actual position
start value (
) considering the set resolution (
).
•
Mode for setting the actual position:
Bit 6 Activate DC-injection braking or short-circuit
braking
DC-injection braking or short-circuit braking is activated via this bit.
Bit 10 Reserved
Bit 11 Reserved
0x6040
CiA: Controlword
0x0000 ... [0x0000] ... 0xFFFF
Mappable CiA 402 control word with bit assignment according to device
profile CiA 402.
Bit 0 Switch on
1 = switch-on
Bit 1 Enable voltage
1 = DC bus: Establish readiness for operation
Bit 2 Quick stop
0 = activate quick stop
Bit 3 Enable operation
1 = enable operation
Bit 4 Operation mode specific
Bit 5 Operation mode specific
Bit 6 Operation mode specific
Bit 7 Fault reset
0-1 edge = reset error
Bit 8 Halt
1 = stop motor (ramping down to frequency setpoint 0 Hz)
Bit 9 Operation mode specific
Operating mode dependent
Bit 14 Release holding brake
1 = releasing holding brake manually
CAUTION!
•
The manually triggered "Release holding brake" command has a direct
impact on the "Release holding brake [115]" trigger. Thus, the holding
brake can be manually released if the power section is switched off.
•
The responsibility for a manual release of the holding brake has the
external trigger source for the "Release holding brake" command.
0x6042
Target velocity
-32768 ... [0] ... 32767 rpm
Setpoint speed (velocity mode).
0x6046:001
Velocity min max amount : Velocity min amount
0 ... [0] ... 0 rpm
Minimum speed (velocity mode).
0x6046:002
Velocity min max amount : Velocity max amount
2147483647 ... [2147483647] ... 2147483647 rpm
Maximum speed (velocity mode).
0x6048:001
Velocity acceleration : Delta speed
0 ... [0] ... 2147483647 rpm
Acceleration: speed interval
0x6048:002
Velocity acceleration : Delta time
0 ... [10] ... 65535 s
Acceleration: time interval
0x6049:001
Velocity deceleration : Delta speed
0 ... [0] ... 2147483647 rpm
Deceleration: speed interval
0x6049:002
Velocity deceleration : Delta time
0 ... [10] ... 65535 s
Deceleration: time interval
Configure speed control
Process input data (CiA 402 objects)
183
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......