11.1.2
Speed limitation
The torque control controls the assigned torque setpoint within the set speed limits. The
actual speed results from the load conditions of the application. For example, high speeds
may occur in a torque control if no counter torque is available (load-free machine).
When the actual speed reaches the set speed limits, it is kept on the respective limit value.
This function is also called "speed limitation".
Details
The lower and upper speed limit for speed limitation can be set independently of each other.
Parameter
Address
Name / setting range / [default setting]
Info
0x2946:001
Speed limitation: Upper speed limit
-479999.999776482 ... [0] ... 479999.999776482 rpm
Upper limit for the speed limitation.
•
Setting is only effective with the selection "Upper speed limit [5]" in .
•
Entry via keypad and Lenze Tools is in rpm!
•
Via RPDO, the unit is vel. unit. and the scaling must be taken into
account.
•
± 480000 rpm = ±2 ^ 31 [n-unit]
0x2946:002
Speed limitation: Lower speed limit
-479999.999776482 ... [0] ... 479999.999776482 rpm
Lower limit for speed limitation.
•
Setting is only effective with the selection "Lower speed limit [5]" in .
•
Entry via keypad and Lenze Tools is in rpm!
•
Via RPDO, the unit is vel. unit. and the scaling must be taken into
account.
•
± 480000 rpm = ±2 ^ 31 [n-unit]
Configuring the torque control
Basic setting
Speed limitation
190
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......