Parameter
Address
Name / setting range / [default setting]
Info
0x2C04:001
Inductance grid points (y) Lss saturation characteris-
tic: y1 = L01 (x = 0.00 %)
0 ... [165] ... 400 %
Saturation characteristic of the leakage inductance.
The linear distribution via the current results from the maximum motor
current (
0x2C04:002
Inductance grid points (y) Lss saturation characteris-
tic: y2 = L02 (x = 6.25 %)
0 ... [200] ... 400 %
0x2C04:003
Inductance grid points (y) Lss saturation characteris-
tic: y3 = L03 (x = 12.50 %)
0 ... [146] ... 400 %
0x2C04:004
Inductance grid points (y) Lss saturation characteris-
tic: y4 = L04 (x = 18.75 %)
0 ... [117] ... 400 %
0x2C04:005
Inductance grid points (y) Lss saturation characteris-
tic: y5 = L05 (x = 25.00 %)
0 ... [97] ... 400 %
0x2C04:006
Inductance grid points (y) Lss saturation characteris-
tic: y6 = L06 (x = 31.25 %)
0 ... [82] ... 400 %
0x2C04:007
Inductance grid points (y) Lss saturation characteris-
tic: y7 = L07 (x = 37.50 %)
0 ... [71] ... 400 %
0x2C04:008
Inductance grid points (y) Lss saturation characteris-
tic: y8 = L08 (x = 42.75 %)
0 ... [62] ... 400 %
0x2C04:009
Inductance grid points (y) Lss saturation characteris-
tic: y9 = L09 (x = 50.00 %)
0 ... [55] ... 400 %
0x2C04:010
Inductance grid points (y) Lss saturation characteris-
tic: y10 = L10 (x = 56.25 %)
0 ... [50] ... 400 %
0x2C04:011
Inductance grid points (y) Lss saturation characteris-
tic: y11 = L11 (x = 62.50 %)
0 ... [46] ... 400 %
0x2C04:012
Inductance grid points (y) Lss saturation characteris-
tic: y12 = L12 (x = 68.75 %)
0 ... [43] ... 400 %
0x2C04:013
Inductance grid points (y) Lss saturation characteris-
tic: y13 = L13 (x = 75.00 %)
0 ... [42] ... 400 %
0x2C04:014
Inductance grid points (y) Lss saturation characteris-
tic: y14 = L14 (x = 81.25 %)
0 ... [41] ... 400 %
0x2C04:015
Inductance grid points (y) Lss saturation characteris-
tic: y15 = L15 (x = 87.50 %)
0 ... [41] ... 400 %
0x2C04:016
Inductance grid points (y) Lss saturation characteris-
tic: y16 = L16 (x = 93.25 %)
0 ... [41] ... 400 %
0x2C04:017
Inductance grid points (y) Lss saturation characteris-
tic: y17 = L17 (x = 100.00 %)
0 ... [41] ... 400 %
0x2C04:018
Inductance grid points (y) Lss saturation characteris-
tic: Activation Lss saturation characteristic
Switch on/off the correction by means of saturation characteristic.
0 Adjustment off
1 Adjustment on
0x2C05
Reference for current grid points (x) Lss saturation
characteristic
0.0 ... [5.4] ... 500.0 A
Setting of the maximum motor current.
Serves as reference value for the scaled current data of the X axis of the
saturation characteristic.
Configuring the motor control
Fine adjustment of the motor model
Correction of the stator leakage inductance (Lss)...
279
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......