Parameter
Address
Name / setting range / [default setting]
Info
0x500A:025
Additional gearbox factor - numerator
1 ... [1] ... 4294967295
•
Setting can only be changed if the inverter is inhibi-
ted.
0x500A:026
Additional gearbox factor - denominator
1 ... [1] ... 4294967295
•
Setting can only be changed if the inverter is inhibi-
ted.
0x500A:033
Gearbox factor - nominator
1 ... [1] ... 4294967295
•
Setting can only be changed if the inverter is inhibi-
ted.
0x500A:034
Gearbox factor - denominator
1 ... [1] ... 4294967295
•
Setting can only be changed if the inverter is inhibi-
ted.
0x500B:033
Gearbox factor - nominator
1 ... [1] ... 4294967295
•
Setting can only be changed if the inverter is inhibi-
ted.
0x500B:034
Gearbox factor - denominator
1 ... [1] ... 4294967295
•
Setting can only be changed if the inverter is inhibi-
ted.
Example of how to calculate the ratio
Example calculation
0x500A : 033 z2*z4 88*72 6336
i
58.667
0x500A : 034 z1*z3
12*9
108
=
=
=
=
=
Gearbox factor numerator
Gearbox factor denominator
Tab. 1: Example of how to calculate the gearbox ratio
Technology application (TA) basic settings
Kinematic settings
Motor/encoder gearbox ratio
48
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......