6.2.11.2
Maximum values for travel profiles
The following parameters can be used to set maximum values for velocity, acceleration and
jerk.
These parameters depend on the mechanics (e.g. the tool used).
The respective limitation is only effective if a non-zero maximum value is set.
If a generated setpoint exceeds the set maximum value (e.g. the maximum velocity), the
motion axis triggers a configured error response.
If the axis is not in a synchronised movement, the profile parameters are automatically limited
to the set maximum values.
A non-synchronised movement is e.g. a positioning or the manual jog function.
A warning indicates that the profile data have been limited.
Parameter
Address
Name / setting range / [default setting]
Info
0x500A:045
Max. velocity
0.0000 ... [0.0000] ... 214748.3647
0x500A:046
Max. acceleration
0.00 ... [0.00] ... 21474836.47
0x500A:047
Max. jerk
0.00 ... [0.00] ... 21474836.47
0x500A:106
Response to error "max. values exceeded"
0 No response
2 Warning
19 Fault > Application quick stop > Quick stop
21 Fault> Application quick stop > Inverter disa-
bled
Technology application (TA) basic settings
Motion settings
Limitations
72
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......