Homing mode -2: CwTorqueLimit
①
Fig. 18: Positive direction to torque limit
Sequence of case
①
:
1
.
The machine part moves in positive direction with reduced torque and profile data set 1.
2
.
The reference is set if the following two conditions for the set blocking time are fulfilled at
the same time:
•
The current speed is lower than the threshold set for standstill detection.
•
The current torque is higher than the set torque limit (homing to end stop).
3
.
Further actions can be selected:
•
Drive stops (default setting).
•
Relative positioning by a set target position.
•
Absolute positioning to a set target position.
Parameter
Address
Name / setting range / [default setting]
Info
0x500A:070
Homing mode
-2 CwTorqueLimit
-1 CcwTorqueLimit
0 SetPositionDirect
1 CcwLimitSwitchCwTP
2 CwLimitSwitchCcwTP
3 CwRpCcwRnTP
5 CcwRpCwRnTP
17 CcwLimitSwitch
18 CwLimitSwitch
19 CwRpCcwRn
21 CcwRpCwRn
33 CcwTP
34 CwTP
99 Reset home position
0x500A:072
Homing: Set position
-214748.3648 ... [0.0000] ... 214748.3647
0x500A:073
Homing: Set position
0.0000 ... [360.0000] ... 214748.3647
0x500A:074
Homing : Velocity 2
0.0000 ... [0.0000] ... 214748.3647
0x500A:075
Homing : Acceleration 1
0.00 ... [720.00] ... 21474836.47
0x500A:076
Homing : Acceleration 2
0.00 ... [360.00] ... 21474836.47
0x500A:077
Homing : Jerk
0.00 ... [7200.00] ... 21474836.47
Technology application (TA) basic settings
Motion settings
Homing
69
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......