6.2.8
Control modes
With the default setting, the axis will always be operated with activated speed control unless
the function used in the application requires a different control type.
The speed control is used when no motor encoder is available.
The speed control is used in the first phase of the reference run, during the search for the
reference signal.
The speed control is used during deceleration with the quick stop function.
The active control type is shown in the Active control mode parameter.
Parameter
Address
Name / setting range / [default setting]
Info
0x500A:090
Default control mode
•
Setting can only be changed if the inverter is inhibi-
ted.
0 Position control via motor encoder
1 Position control via load encoder
10 Speed control via motor encoder
0x500A:091
Actual control mode
•
Read only
0 Position control via motor encoder
1 Position control via load encoder
10 Speed control via motor encoder
20 Torque control
0x500A:092
Load encoder selection
•
Setting can only be changed if the inverter is inhibi-
ted.
-
Encoder_Axis
0x500A:093
Position controller gain
0.0000 ... [20.0000] ... 214748.3647 1/s
0x500A:094
Load encoder output limit
0.0000 ... [100000.0000] ... 214748.3647
0x500A:095
Position controller output
•
Read only
Technology application (TA) basic settings
Motion settings
Control modes
57
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......