Glossary
green constant sensor
must turn on before the ready signal begins and turn off after the
ready signal ends; that is, it must stay actuated constantly during
the ready signal
green quick check sensor
like a green sensor,
except
that it cannot stay on or turn on
outside the ready signal
green sensor
must actuate at least momentarily during the ready signal
green special sensor
designed to effectively monitor slug ejection (see Chapter 1)
hand-speed constant
indicates how far one could normally move one's hand and arm
in one second; OSHA recommended measurement at 63 inches-
per-second
HELP key
key located in the center of the cursor keys that brings up a help
screen when pressed
Hot keys
a special use of the function keys in Run mode; user programs a
function key to bring up a frequently used screen
impedance
refers to the opposition to the flow of electric current; some die
protection controls have inputs with different impedances for
electromechanical sensors; as a rule of thumb: use a high-
impedance input if the part is dirty or covered with a non-
conductive lubricant; use a low-impedance input if the part is
covered with a water-based or conductive lubricant
Interrupted Stroke
occurs when the press has been emergency-stopped before the
completion of the stroke by either the operator or an automatic
device for personnel or equipment protection
keyboard
consists of various key and a numeric keypad described below;
used along with the display to make settings
lockout
function built into the system which provides an added safety
feature to the product; see "lockout message"
lockout message
a lockout mode message appear on SmartPAC's display, which
indicates that a serious error condition ("lockout") has occurred
(see Chapter 7)
manual enable
die protection mode where sensors are manually enabled or
disabled by the operator
menu
display enabling one to carry out a specific task such as: set
counters, adjust settings, etc.
Содержание SmartPAC 2
Страница 192: ...1126800 SmartPAC 2 with WPC Integration Page 170 Chapter 2 Installing SmartPAC 2 and WPC ...
Страница 222: ...1126800 SmartPAC 2 with WPC Integration Page 200 Chapter 3 SmartPAC 2 Keyboard Displays and Operating Modes ...
Страница 294: ...1126800 SmartPAC 2 with WPC Integration Page 272 Chapter 4 SmartPAC 2 Initialization Mode ...
Страница 342: ...1126800 SmartPAC 2 with WPC Integration page 320 Chapter 5 SmartPAC 2 Program Mode ...
Страница 404: ...1126800 SmartPAC 2 with WPC Integration Page 382 Chapter 6 SmartPAC 2 Run Mode ...
Страница 448: ...1126800 SmartPAC 2 with WPC Integration Page 426 Chapter 7 SmartPAC 2 Fault Messages ...
Страница 476: ...1126800 SmartPAC 2 with WPC Integration page 454 Appendix C Updating SmartPAC 2 Firmware ...
Страница 478: ...1126800 SmartPAC 2 with WPC Integration page 456 Appendix D SmartView Remote Viewing and E mail Setup ...
Страница 480: ...1126800 SmartPAC 2 with WPC Integration page 458 Appendix E Upgrade from Original SmartPAC to SmartPAC 2 ...
Страница 482: ...1126800 SmartPAC 2 with WPC Integration page 460 Appendix F Replacing SmartPAC 2 PC Board ...
Страница 492: ...1126800 SmartPAC 2 with WPC Integration page 470 Glossary ...