SmartPAC 2 with WPC Integration
1126800
Excerpts from OSHA Regulations and ANSI Standards Appendix A
page 433
Extracts from ANSI B11.1-2001 8.5.3
Standard Requirements
Explanatory Information
8.5.3.11
The device shall be provided with a
means that visibly indicates when it is
functioning properly. The device shall also
indicate which sections, if any, have been
blanked out and whether floating blanking
features are in use.
E8.5.3.11
Red and green indicator lamps or
other means that can easily be seen by the
operator and others should be used to indicate
that the device is bypassed.
For radio frequency devices, it is useful to
observe a display such as a meter or signal lamp
to indicate the degree of penetration as an aid to
set-up and shaping of the field as well as the
separate signal to indicate intrusion resulting in
a STOP command.
8.5.3.12
The device shall not fail to respond to
the presence of the individual's hand or other
body part due to the presence of a reflective
object or workpiece.
8.5.3.13
The device shall conform to the
requirements of 6.8 (and 8.7). in the event of a
power failure to the device, the device shall
initiate a stop command to the press control
system.
8.5.3.14
The interface of the presence-sensing
device to the press control shall conform to the
requirements of 6.8 (and 8.7).
8.5.3.15
The sensitivity of the device to
intrusion shall not be adversely affected by
changing conditions around the press.
E8.5.3.15
Some devices can be affected by
changes in the conditions around the press
production system such as the placement of
parts and tote boxes, grounding conditions or
the operator, or the movement of forklift trucks.
8.5.3.16
The effective sensing field of the
device shall be located at distance from the
nearest point-of-operation hazard so that
individuals cannot reach the point of operation
with a hand or other body part before cessation
of motion during the hazardous portion of the
cycle (stroke).
E8.5.3.16
The total stopping time of the press
should include the total response time of the
presence-sensing device, as stated by the
supplier, the response time of the interface, the
response time of the control system, and the
rime it takes the press to cease slide motion.
The following formula should be used when
calculating the safety distance:
Ds = K (Ts + Tc + Tr + Tbm) + Dpf
Содержание SmartPAC 2
Страница 192: ...1126800 SmartPAC 2 with WPC Integration Page 170 Chapter 2 Installing SmartPAC 2 and WPC ...
Страница 222: ...1126800 SmartPAC 2 with WPC Integration Page 200 Chapter 3 SmartPAC 2 Keyboard Displays and Operating Modes ...
Страница 294: ...1126800 SmartPAC 2 with WPC Integration Page 272 Chapter 4 SmartPAC 2 Initialization Mode ...
Страница 342: ...1126800 SmartPAC 2 with WPC Integration page 320 Chapter 5 SmartPAC 2 Program Mode ...
Страница 404: ...1126800 SmartPAC 2 with WPC Integration Page 382 Chapter 6 SmartPAC 2 Run Mode ...
Страница 448: ...1126800 SmartPAC 2 with WPC Integration Page 426 Chapter 7 SmartPAC 2 Fault Messages ...
Страница 476: ...1126800 SmartPAC 2 with WPC Integration page 454 Appendix C Updating SmartPAC 2 Firmware ...
Страница 478: ...1126800 SmartPAC 2 with WPC Integration page 456 Appendix D SmartView Remote Viewing and E mail Setup ...
Страница 480: ...1126800 SmartPAC 2 with WPC Integration page 458 Appendix E Upgrade from Original SmartPAC to SmartPAC 2 ...
Страница 482: ...1126800 SmartPAC 2 with WPC Integration page 460 Appendix F Replacing SmartPAC 2 PC Board ...
Страница 492: ...1126800 SmartPAC 2 with WPC Integration page 470 Glossary ...