SmartPAC 2 with WPC Integration User Manual
1126800
Glossary
page 463
cursor keys
used to move the selection bar over the item on the display to be
selected; also used to make certain programming and adjusting
entries, and to select alphabetic characters and special symbols
when naming the press, tools, cam channels, and sensors
depth penetration factor
measurement of how far an object, like an operator's hand, can
move through the light curtain before the light curtain reacts
display
the screen on the SmartPAC 2 that displays text and graphics,
used along with the keyboard to make and adjust settings, to
load tool numbers, and to view diagnostic messages
dual diverse redundancy
the latest technology in maintaining optimum clutch/brake
control and operator safety, where both of the micro-processor
systems ("dual micro-processors") function independently of
each other, have separate power supplies, and provide separate
information to the operator
Dual Safety Valve
controls the air flow that operates the clutch and brake of the
press
dwell duration time
how long the cam channel and/or sensor are expected to stay
activated
emergency stop
signal sent to the press as soon as a malfunction occurs; should
be used when the operator wants the press to stop immediately
enable mode
ability to activate or deactivate sensors connected to the die
protection mode; see also
manual enable
;
auto enable by tool
;
and
auto enable by sensor
ENTER key
used after highlighting a selection or keying in a value on the
display
fault (error) message
diagnostics that indicate why the press was stopped, identify the
problem, and suggest how to correct
flywheel timer
proper setting of this WPC feature prohibits starting the motor in
the reverse direction or activating the Bar mode while the
flywheel is still turning
function keys
periodically used to perform certain tasks in SmartPAC; the
message on the LCD display will identify the specific function
key number to depress (from
F1
to
F8
)
good parts counter
increments only "good" parts if the die protection and/or tonnage
monitoring option does not generate a fault
Содержание SmartPAC 2
Страница 192: ...1126800 SmartPAC 2 with WPC Integration Page 170 Chapter 2 Installing SmartPAC 2 and WPC ...
Страница 222: ...1126800 SmartPAC 2 with WPC Integration Page 200 Chapter 3 SmartPAC 2 Keyboard Displays and Operating Modes ...
Страница 294: ...1126800 SmartPAC 2 with WPC Integration Page 272 Chapter 4 SmartPAC 2 Initialization Mode ...
Страница 342: ...1126800 SmartPAC 2 with WPC Integration page 320 Chapter 5 SmartPAC 2 Program Mode ...
Страница 404: ...1126800 SmartPAC 2 with WPC Integration Page 382 Chapter 6 SmartPAC 2 Run Mode ...
Страница 448: ...1126800 SmartPAC 2 with WPC Integration Page 426 Chapter 7 SmartPAC 2 Fault Messages ...
Страница 476: ...1126800 SmartPAC 2 with WPC Integration page 454 Appendix C Updating SmartPAC 2 Firmware ...
Страница 478: ...1126800 SmartPAC 2 with WPC Integration page 456 Appendix D SmartView Remote Viewing and E mail Setup ...
Страница 480: ...1126800 SmartPAC 2 with WPC Integration page 458 Appendix E Upgrade from Original SmartPAC to SmartPAC 2 ...
Страница 482: ...1126800 SmartPAC 2 with WPC Integration page 460 Appendix F Replacing SmartPAC 2 PC Board ...
Страница 492: ...1126800 SmartPAC 2 with WPC Integration page 470 Glossary ...