1126800
SmartPAC 2 with WPC Integration
Page 410
Chapter 7
SmartPAC 2 Fault Messages
"Angle Resolver Failure"
Explanation:
The problem may be that wiring in the resolver circuit to SmartPAC 2 is
loose or bad or that the resolver has failed. It may also be that the press is
going faster than 800 (or 1600 SPM, depending on the speed setting at
SmartPAC 2).
Remedy:
If SmartPAC 2's rated press speed is exceeded, reduce the speed. If not,
check the resolver wiring and connections for shorts, breaks, or loose
connections. See Chapter 2 "Mounting the resolver" or “Setting high
speed version of SmartPAC 2" (be sure you set the speed correctly). If
these are not the problem, the resolver may need to be replaced. Call the
factory for assistance.
NOTICE
To clear this fault, you must turn SmartPAC 2 off. (RESET will not work.)
"Input check circuit failure"
Explanation:
The resolver turned five times (in other words, the press was running), but
SmartPAC 2 received no signal into the input check circuit.
Remedy:
The input check circuit has not been connected or wired properly. If this
message occurs when the press stops, your press is taking more than five
revolutions to stop after the brake is activated. You should check your
brake for wear. For wiring the input check circuit, see "Connecting AC
wiring, stop circuits and input check circuit" in Chapter 2. Make sure input
check voltage switch S101 correctly set to 12-60 VDC, as shown in Figure
2 - 21.
E-Stop errors
Explanation:
If a message appears on the display that references "ESTOP,” this has to
do with either of the emergency stop relay circuits not working
satisfactorily. One or both of these E-STOP circuits may be defective.
Remedy:
You cannot reset the error. Instead, turn the unit off, then on. If the error
continues to occur, contact Wintriss Tech Support.
Содержание SmartPAC 2
Страница 192: ...1126800 SmartPAC 2 with WPC Integration Page 170 Chapter 2 Installing SmartPAC 2 and WPC ...
Страница 222: ...1126800 SmartPAC 2 with WPC Integration Page 200 Chapter 3 SmartPAC 2 Keyboard Displays and Operating Modes ...
Страница 294: ...1126800 SmartPAC 2 with WPC Integration Page 272 Chapter 4 SmartPAC 2 Initialization Mode ...
Страница 342: ...1126800 SmartPAC 2 with WPC Integration page 320 Chapter 5 SmartPAC 2 Program Mode ...
Страница 404: ...1126800 SmartPAC 2 with WPC Integration Page 382 Chapter 6 SmartPAC 2 Run Mode ...
Страница 448: ...1126800 SmartPAC 2 with WPC Integration Page 426 Chapter 7 SmartPAC 2 Fault Messages ...
Страница 476: ...1126800 SmartPAC 2 with WPC Integration page 454 Appendix C Updating SmartPAC 2 Firmware ...
Страница 478: ...1126800 SmartPAC 2 with WPC Integration page 456 Appendix D SmartView Remote Viewing and E mail Setup ...
Страница 480: ...1126800 SmartPAC 2 with WPC Integration page 458 Appendix E Upgrade from Original SmartPAC to SmartPAC 2 ...
Страница 482: ...1126800 SmartPAC 2 with WPC Integration page 460 Appendix F Replacing SmartPAC 2 PC Board ...
Страница 492: ...1126800 SmartPAC 2 with WPC Integration page 470 Glossary ...