Chapter 5. FUNCTIONS
●
RUN
The RUN mode indicates that the program is run sequentially.
MV output and events operate during PID control, ON-OFF control and other types of
control. In the program RUN mode, program operation progresses according as time
elapses. Note, however, that G.SOAK (guarantee soak) wait, like the HOLD mode, halts
program operation.
●
HOLD
The HOLD mode temporarily halts program operation.
Note, however, that, like the RUN mode, MV output and events operate during PID
operation, ON-OFF control and other types of control. During constant value control the
HOLD mode cannot be invoked.
●
FAST
The FAST mode is essentially a speeded-up version of the RUN mode. The time factor
is selected using variable parameter
PA39
. MV output and events operate during PID
control, ON-OFF control and other types of control. G.SOAK (guarantee soak) settings
are ignored.
During constant value control the FAST mode cannot be invoked.
●
END
The END mode indicates the state of a program that has run its course.
When a program stops at the end, MV output and events operate during PID control,
ON-OFF control and other types of control.
During constant value control the END mode cannot be invoked.
●
READY FAST
The READY FAST mode is a combination of the READY and FAST modes.
MV output, SP output and events operate in the same way as in the READY mode.
Program numbers and segment numbers cannot be selected. Parameters that can only be
changed in the READY mode and memory card operation cannot be performed in this
mode.
During constant value control the READY FAST mode cannot be invoked.
●
AUTO
The AUTO mode performs automatic operation. MV outputs can be used depending on
DCP551 control. (Note, however, that when programmer functions are selected,
DCP551 dependent SP outputs operate.)
●
MANUAL
The MANUAL mode performs manual operation.
The “
↑↑
”, “
↓↓
”, “
←
←
” and “
→
→
” console keys can be used to change communications and
MV output.
(Note, however, that when setter functions are selected, communications and SP output
can be changed.)
5-25
Содержание DCP550
Страница 1: ...EN1I 6186 Issue 13 04 08 DCP551 Mark ΙΙ Digital Control Programmer User s Manual www honeyvell energy ...
Страница 115: ...Chapter 7 PARAMETER SETUP Settings by event type For information on event operations see Events pages 5 5 to 5 15 7 13 ...
Страница 117: ...Chapter 7 PARAMETER SETUP 0 1 02 3 02 3 0 1 1 4 5 1 4 6 1 4 5 2 2 2 7 15 ...
Страница 119: ...Chapter 7 PARAMETER SETUP 0 11 2 2 3 3 7 17 ...
Страница 122: ...Chapter 7 PARAMETER SETUP d A5 tP A5 CP A5 rE A5 P A6 I A6 d A6 rE A6 CP A6 tP A6 P A7 I A7 d A7 rE A7 CP A7 tP A7 7 20 ...
Страница 209: ...Chapter 12 CALIBRATION Figure 12 11 Current Outputs 12 18 ...
Страница 229: ......
Страница 230: ...No CP UM 5024E ...