Chapter 10. TROUBLESHOOTING
10-3 When the BAT LED Flashes
HANDLING PRECAUTIONS
Batteries that have been stored for long periods have been subject to self-dis-
charge and have a short service life. If required, buy new batteries.
■
BAT LED flashes
The
BAT
LED starts flashing when low battery voltage is detected. The voltage level set
in memory that trigger the LED is higher than minimum level required for storing data.
Thus data loss is thus not imminent when the LED starts flashing.
Note, however, that memory data corruption has probably occurred when the
BAT
LED
starts flashing at power up after the DCP551 has been stored for long periods discon-
nected from the power line.
■
Replacing the battery
Parameter settings and program settings are stored in RAM memory. The RAM is
backed up by a battery and data persist through a power down. When the battery is
depleted, turning off the DCP551 causes the data stored in RAM to be lost.
●
Items to be provided by the user
• Phillips screwdriver
• New lithium battery: model number 81446140-001
10-8
CAUTION
Be sure to turn off the power supply when you are replacing the batteries.
Failure to heed this warning may lead to electric shock.
Batteries should be kept out of reach of children, since they may swallow
them. Should a child swallow a battery, contact a doctor immediately.
• Make sure that the batteries are inserted with the plus (+) and minus (–) poles correctly oriented.
• Do not use damaged batteries or batteries that leak.
• Do not throw batteries into a fire, recharge, disassemble or expose them to heat.
• Store batteries in a cool, dry place.
Failure to heed these cautions may result in burns or battery leakage.
Be sure not to touch internal components during battery replacement or
just after the power has been turned. This may result in burn injuries.
When disposing of used batteries at the user site, observe local bylaws.
Before you touch internal components, be sure to discharge any static
electricity on your body by touching a metal ground connector. Failure to
heed this caution may lead to equipment damage.
Содержание DCP550
Страница 1: ...EN1I 6186 Issue 13 04 08 DCP551 Mark ΙΙ Digital Control Programmer User s Manual www honeyvell energy ...
Страница 115: ...Chapter 7 PARAMETER SETUP Settings by event type For information on event operations see Events pages 5 5 to 5 15 7 13 ...
Страница 117: ...Chapter 7 PARAMETER SETUP 0 1 02 3 02 3 0 1 1 4 5 1 4 6 1 4 5 2 2 2 7 15 ...
Страница 119: ...Chapter 7 PARAMETER SETUP 0 11 2 2 3 3 7 17 ...
Страница 122: ...Chapter 7 PARAMETER SETUP d A5 tP A5 CP A5 rE A5 P A6 I A6 d A6 rE A6 CP A6 tP A6 P A7 I A7 d A7 rE A7 CP A7 tP A7 7 20 ...
Страница 209: ...Chapter 12 CALIBRATION Figure 12 11 Current Outputs 12 18 ...
Страница 229: ......
Страница 230: ...No CP UM 5024E ...