Chapter 7. PARAMETER SETUP
PA 31
Event on delay
Group 1 event number
31
0 to 16
[Description:]
A setting of 0 generates no delay.
0
PA 32
Event on delay
Group 1 delay time
32
0.0 to 3000.0sec
[Description:]
When
PA31
is set to 0, Ò-----Ó is displayed and setting cannot be performed.
0.0
PA 33
Event on delay
Group 2 event number
33
0 to 16
[Description:]
A setting of 0 generates no delay.
0
PA 34
Event on delay
Group 2 delay time
34
0.0 to 3000.0sec
[Description:]
When
PA33
is set to 0, Ò-----Ó is displayed and setting cannot be performed.
0.0
PA 35
Event on delay
Group 3 event number
35
0 to 16
[Description:]
A setting of 0 generates no delay.
0
PA 36
Event on delay
Group 3 delay time
36
0.0 to 3000.0sec
[Description:]
When
PA35
is set to 0, Ò------Ó is displayed and setting cannot be performed.
0.0
PA 37
Event on delay
Group 4 event number
37
0 to 16
[Description:]
A setting of 0 generates no delay.
0
PA 38
Event on delay
Group 4 delay time
38
0.0 to 3000.0sec
[Description:]
When
PA37
is set to 0, Ò-----Ó is displayed and setting cannot be performed.
0.0
PA 41
EG1 LED display event
number
41
0 to 16
[Description:]
A setting of 0 turns off the EG1 LED.
0
PA 42
EG2 LED display event
number
42
0 to 16
[Description:]
A setting of 0 turns off the EG2 LED.
0
PA 43
PID computation initialize
43
0: No initialization during advance processing and PID group
change.
1: Initializes during advance processing but not during PID
group change.
2: No initialization during advance processing but initializes
0
PA 39
FAST X
39
0 : 2X
1 : 10X
2 : 60X
3 : 120X
[Description:]
When setup data
C62
is set to 1 (program time unit: minutes,
seconds), settings 3 and 4 produce a speed of 10 X.
When
C62
is set to 2 (program time unit: 0.1sec), the FAST
mode is not available.
0
[Description:]
Ò-----Óis displayed and setting cannot be performed.
-----
PA 24
24
Unused
-----
PA 25
25
Unused
-----
PA 26
26
Unused
-----
PA 27
27
Unused
-----
PA 28
28
Unused
-----
PA 29
29
Unused
-----
PA 30
30
Unused
[Description:]
Ò-----Óis displayed and setting cannot be performed.
----
PA 44
44
Unused
[Description:]
Ò-----Óis displayed and setting cannot be performed.
-----
PA 40
40
Unused
----
PA 45
45
Unused
0.1 to 60.0sec
2.0
PA 46
46
G.SOAK time
----
PA 47
47
Unused
----
PA 48
48
Unused
----
PA 49
49
Unused
7-6
Содержание DCP550
Страница 1: ...EN1I 6186 Issue 13 04 08 DCP551 Mark ΙΙ Digital Control Programmer User s Manual www honeyvell energy ...
Страница 115: ...Chapter 7 PARAMETER SETUP Settings by event type For information on event operations see Events pages 5 5 to 5 15 7 13 ...
Страница 117: ...Chapter 7 PARAMETER SETUP 0 1 02 3 02 3 0 1 1 4 5 1 4 6 1 4 5 2 2 2 7 15 ...
Страница 119: ...Chapter 7 PARAMETER SETUP 0 11 2 2 3 3 7 17 ...
Страница 122: ...Chapter 7 PARAMETER SETUP d A5 tP A5 CP A5 rE A5 P A6 I A6 d A6 rE A6 CP A6 tP A6 P A7 I A7 d A7 rE A7 CP A7 tP A7 7 20 ...
Страница 209: ...Chapter 12 CALIBRATION Figure 12 11 Current Outputs 12 18 ...
Страница 229: ......
Страница 230: ...No CP UM 5024E ...