Chapter 18
18-7
18.2.3 Making Connections (SST in use)
0011-6753
[Requirements]
- PC to which the SST (version 3.21 or later) has
been installed and the system software has been
copied
- twisted-pair cross cable
10Base-T: Category 3 or 5
100Base-TX: Category 5
[Procedure]
1) Start up the PC.
2) Check the network settings of the PC.
2-1) Start the command prompt, and type in
"
IPCONFIG
," and press the Return key.
2-2) Check to be sure that the network settings
appearing on the screen are as follows; if not,
change the PC network settings:
IP address: 172.16.1.160
Subnet mask: 255.255.255.0
Default gateway: any
Do not use the following IP addresses:
- 172.16.1.0
- 172.16.1.100
- 172.16.1.255
3) Check to make sure that the Execute/Memory
lamp on the control panel is off; then, turn off
the main power switch.
3-1) Hold down the power switch on the control
panel for 3 sec or more.
3-2) Go through the shut-down instructions
appearing on the control panel screen so that
the main power switch may be turned off.
3-3) Turn off the main power switch.
4) Connect the PC to the machine with a cross
cable.
F-18-13
5) Set the machine to the appropriate mode:
- Normal Mode
Turn on the main power switch while
holding down the keys 1 and 7.
When the machine has started, make the
following selections in service mode:
COPIER > FUNCTION > SYSTEM >
DOWNLOAD; then, click [OK].
-
Safe Mode
Turn on the main power switch while
holding down the keys 2 and 8. In response,
the machine will start up in safe mode.
18.2.4 Making Connections (USB device
in use)
0011-6754
[Requirements]
- USB device to which the system software has
been copied.
[Procedure]
1) Check to make sure that the Execute/Memory
on the control panel is off; then, turn off the
main power switch as follows:
1-1) Hold down the control panel power switch
for 3 sec or more.
1-2) Go through the shut-down instructions.
1-3) Turn off the main power switch.
2) Connect the USB device [2] to the USB port
[1].
F-18-14
3) If a network cable is connected to the machine,
disconnect it.
4) Set the machine to the appropriate download
mode:
-
Normal Mode
Turn on the main power switch while
holding down the keys 1 and 7.
When the machine has started up, make the
following selections in service mode, and
press [OK]:
COPIER > FUNCTION > SYSTEM >
DOWNLOAD.
-
Safe Mode
Turn on the main power switch while
holding down the keys 2 and 8 so that the
machine will start up in safe mode.
address: 172.16.1.100
net mask: 255.255.255.0
IP sddress: 172
Subnet mask: 25
Cross cable
10Base-T: category 3, 5 or later
100Base-TX: category 5 or later
[1]
[2]
Содержание IMAGERUNNER 7095 PRINTER
Страница 20: ...Chapter 1 Introduction...
Страница 46: ...Chapter 2 Installation...
Страница 88: ...Chapter 3 Basic Operation...
Страница 94: ...Chapter 4 Main Controller...
Страница 116: ...Chapter 5 Original Exposure System...
Страница 165: ...Laser Exposure Chapter 6...
Страница 175: ...Chapter 7 Image Formation...
Страница 180: ...Chapter 7 7 3 7 3 Basic Sequence 7 3 1 Basic Sequence 0010 8038 F 7 3 ON ON WMUPR WMUP STBY OFF 100msec...
Страница 231: ...Chapter 8 Pickup Feeding System...
Страница 287: ...Chapter 9 Fixing System...
Страница 312: ...Chapter 10 External and Controls...
Страница 346: ...Chapter 11 MEAP...
Страница 350: ...Chapter 12 RDS...
Страница 360: ...Chapter 13 Maintenance Inspection...
Страница 375: ...Chapter 14 Standards Adjustments...
Страница 407: ...Chapter 15 Correcting Faulty Images...
Страница 433: ...Chapter 16 Self Diagnosis...
Страница 460: ...Chapter 17 Service Mode...
Страница 559: ...Chapter 18 Upgrading...
Страница 583: ...Chapter 19 Service Tools...
Страница 584: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 Special Tools Table 19 1 19 1 2 Solvents Oils 19 2...
Страница 588: ...APPENDIX...
Страница 615: ......