5.3.3 Controlling the Scanning Lamp
5.3.3.1 Overview <iR7105/7095>
0010-7891
The following shows the items of control and the components of the control system associated with the
activation of the scanning lamp:
1) Controlling the Activation
The machine turns on or off the scanning lamp using the drive signal (XE-ON) generated by the CPU
on the reader controller PCB. In response to the signal, the inverter PCB generates high-frequency high
voltage in the activation motor circuit using the drive voltage (+24 V) supplied by the reader controller
PCB, thus turning on the scanning lamp.
2) Detecting an Error
The machine identifies an error in the intensity of light as an activation error occurring when the lamp
is initially turned on (shading correction).
ERROR CODE:
E225
-0001: at time of shading, the detected intensity of light falls short of a specific level.
-0002: in ADF mode, the intensity of light between originals falls short of a specific level.
F-5-20
5.3.3.2 Overview <iR7086>
0010-7892
The following shows the items of control and the components of the control system associated with the
activation of the scanning lamp:
1) Controlling the Activation
The machine turns on or off the scanning lamp using the drive signal (XE-ON) generated by the CPU
on the reader controller PCB. In response to the signal, the inverter PCB generates high-frequency high
voltage in the activation motor circuit using the drive voltage (+24 V) supplied by the reader controller
PCB, thus turning on the scanning lamp.
2) Detecting an Error
The machine identifies an error in the intensity of light as an activation error occurring when the lamp
is initially turned on (shading correction).
ERROR CODE:
E225
-0001: at time of shading, the detected intensity of light falls short of a specific level.
-0002: in ADF mode, the intensity of light between originals falls short of a specific level.
F-5-21
Inverter PCB
Scanning lamp
Reader control
PCB
J601
J203
Activation control circuit
LA1
CPU
GND
GND
GND
GND
XE-ON
24V
24V
XSYNC
24V
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
Inverter PCB
scanning lamp
Activation
control
circuit
J601
J206
Reader controller PCB
LA1
CPU
GND
GND
GND
GND
XE-ON
24V
24V
XSYNC
24V
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
Содержание IMAGERUNNER 7095 PRINTER
Страница 20: ...Chapter 1 Introduction...
Страница 46: ...Chapter 2 Installation...
Страница 88: ...Chapter 3 Basic Operation...
Страница 94: ...Chapter 4 Main Controller...
Страница 116: ...Chapter 5 Original Exposure System...
Страница 165: ...Laser Exposure Chapter 6...
Страница 175: ...Chapter 7 Image Formation...
Страница 180: ...Chapter 7 7 3 7 3 Basic Sequence 7 3 1 Basic Sequence 0010 8038 F 7 3 ON ON WMUPR WMUP STBY OFF 100msec...
Страница 231: ...Chapter 8 Pickup Feeding System...
Страница 287: ...Chapter 9 Fixing System...
Страница 312: ...Chapter 10 External and Controls...
Страница 346: ...Chapter 11 MEAP...
Страница 350: ...Chapter 12 RDS...
Страница 360: ...Chapter 13 Maintenance Inspection...
Страница 375: ...Chapter 14 Standards Adjustments...
Страница 407: ...Chapter 15 Correcting Faulty Images...
Страница 433: ...Chapter 16 Self Diagnosis...
Страница 460: ...Chapter 17 Service Mode...
Страница 559: ...Chapter 18 Upgrading...
Страница 583: ...Chapter 19 Service Tools...
Страница 584: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 Special Tools Table 19 1 19 1 2 Solvents Oils 19 2...
Страница 588: ...APPENDIX...
Страница 615: ......