16.2 Error Code Details
16.2.1 Error Code Details
0011-6725
T-16-2
Code
Description
Remedial action
*: model equipped with DADF-Q1 (outside Japan, iR7105/7095; inside Japan: iR7105/7095/7086).
**: model equipped with DADF-M1 (outside Japan: iR7086).
E000
The fixing unit has overheated.
After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
0000
The reading of the main thermistor is less than 70 deg
C 3.5 min after power-on.
Check the mounting/soiling of the main
thermistor. Replace the fixing heater.
Replace the
main thermistor. Replace the AC driver
PCB. Replace the DC controller PCB.
0010
The power has been turned off and then on without
resetting the error.
Reset the error.
(COPIER>FUNCTION>CLEAR>ERR)
E001
The fixing unit has overheated.
After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
0001
The reading of the main thermistor or the sub
thermistor is 230 deg C or more for 2 sec.
(hardware detection)
Replace the AC driver PCB. Replace the
DC controller PCB.
0002
The reading of the main thermistor or the sub
thermistor is 230 deg C or more for 2 sec or
more. (software detection)
Check the mounting/soiling of the main
thermistor. Replace the main thermistor.
Replace
the sub thermistor. Replace the AC driver
PCB. Replace the DC controller PCB.
0003
The difference in the readings of the main thermistor
and the sub thermistor is 50 deg C for
1 sec. (main thermistor reading>sub thermistor
reading)
Check the mounting/soiling of the main
thermistor. Replace the main thermistor.
Replace
the AC driver PCB. Replace the DC
controller PCB.
0004
The difference in the readings of the main thermistor
and the sub thermistor is 50 deg C for
1 sec or more. (main thermistor reading>/=sub
thermistor reading)
0010
The power has been turned off and then on without
resetting the error.
Reset the error.
(COPIER>FUNCTION>CLEAR>ERR)
E002
The fixing unit has overheated.
After correcting the error, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
0000
The reading of the main thermistor has exceeded 70
deg C, but does not reach 100 deg C
within 2.5 sec thereafter.
Disconnect and then connect J508 of the
DC controller PCB. Disconnect and then
connect
the connectors of the fixing unit. Check the
wiring between the main/sub thermistor
and
the DC controller. Check the mounting/
soiling of the main thermistor. Replace the
fixing
heater. Replace the AC driver PCB.
Replace the DC controller PCB.
0001
The reading of the main thermistor has exceeded 100
deg C, but does not reach 150 deg C
within 2.5 min thereafter.
0010
The power has been turned on without resetting the
error.
Reset the error.
(COPIER>FUNCTION>CLEAR>ERR)
E003
The fixing unit temperature is abnormally low.
After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
Содержание IMAGERUNNER 7095 PRINTER
Страница 20: ...Chapter 1 Introduction...
Страница 46: ...Chapter 2 Installation...
Страница 88: ...Chapter 3 Basic Operation...
Страница 94: ...Chapter 4 Main Controller...
Страница 116: ...Chapter 5 Original Exposure System...
Страница 165: ...Laser Exposure Chapter 6...
Страница 175: ...Chapter 7 Image Formation...
Страница 180: ...Chapter 7 7 3 7 3 Basic Sequence 7 3 1 Basic Sequence 0010 8038 F 7 3 ON ON WMUPR WMUP STBY OFF 100msec...
Страница 231: ...Chapter 8 Pickup Feeding System...
Страница 287: ...Chapter 9 Fixing System...
Страница 312: ...Chapter 10 External and Controls...
Страница 346: ...Chapter 11 MEAP...
Страница 350: ...Chapter 12 RDS...
Страница 360: ...Chapter 13 Maintenance Inspection...
Страница 375: ...Chapter 14 Standards Adjustments...
Страница 407: ...Chapter 15 Correcting Faulty Images...
Страница 433: ...Chapter 16 Self Diagnosis...
Страница 460: ...Chapter 17 Service Mode...
Страница 559: ...Chapter 18 Upgrading...
Страница 583: ...Chapter 19 Service Tools...
Страница 584: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 Special Tools Table 19 1 19 1 2 Solvents Oils 19 2...
Страница 588: ...APPENDIX...
Страница 615: ......