Chapter 13
13-11
Keep the blade using the plate, and tighten the
screws.
- fully tighten screws 6 through 10.
13) Apply toner to the edge of the cleaning blade
where the blade comes into contact with the
photosensitive drum, and mount the blade:
F-13-12
When mounting the cleaning blade, be sure to put
the blade reinforcing plate between the blade sup-
port plate and the blade back plate.
After mounting the cleaning blade, turn the drum.
If the cleaning blade fails to catch the toner, re-
peat the foregoing steps. If tightening the screws
for a second time fails to correct the fault, replace
the cleaning blade.
Blade support plate
Blade reinforcing plate
Blade retainer
Blade back plate
Blade vibration unit
Содержание IMAGERUNNER 7095 PRINTER
Страница 20: ...Chapter 1 Introduction...
Страница 46: ...Chapter 2 Installation...
Страница 88: ...Chapter 3 Basic Operation...
Страница 94: ...Chapter 4 Main Controller...
Страница 116: ...Chapter 5 Original Exposure System...
Страница 165: ...Laser Exposure Chapter 6...
Страница 175: ...Chapter 7 Image Formation...
Страница 180: ...Chapter 7 7 3 7 3 Basic Sequence 7 3 1 Basic Sequence 0010 8038 F 7 3 ON ON WMUPR WMUP STBY OFF 100msec...
Страница 231: ...Chapter 8 Pickup Feeding System...
Страница 287: ...Chapter 9 Fixing System...
Страница 312: ...Chapter 10 External and Controls...
Страница 346: ...Chapter 11 MEAP...
Страница 350: ...Chapter 12 RDS...
Страница 360: ...Chapter 13 Maintenance Inspection...
Страница 375: ...Chapter 14 Standards Adjustments...
Страница 407: ...Chapter 15 Correcting Faulty Images...
Страница 433: ...Chapter 16 Self Diagnosis...
Страница 460: ...Chapter 17 Service Mode...
Страница 559: ...Chapter 18 Upgrading...
Страница 583: ...Chapter 19 Service Tools...
Страница 584: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 Special Tools Table 19 1 19 1 2 Solvents Oils 19 2...
Страница 588: ...APPENDIX...
Страница 615: ......