Chapter 16
16-7
0001
After the start of horizontal registration HP detection,
the HP sensor is not off within 5 sec
(i.e., not leaving home position).
MEMO:
If an error is detected in the course of horizontal
registration HP detection at power-on, the
machine will indicate the presence of a jam.
At the start of horizontal registration
detection in the course of printing, the
horizontal
registration detection operation for
downstream paper does not end within 5
sec.
0002
After the start of horizontal registration HP detection,
the home position is not detected
within 5 sec.
MEMO:
If an error is detected in the course of horizontal
registration HP detection at power-on, the
machine will indicate the presence of a jam.
0003
Replace the horizontal registration HP sensor. Replace
the horizontal registration motor.
Replace the stackless transport driver PCB. Replace
the DC controller PCB.
E065
The high-voltage output has a fault. (primary charging assembly)
0000
A fault (leak) is detected when high voltage is supplied
to the primary charging assembly.
Remove and then mount the primary
charging assembly. Check for soiling.
Disconnect and
then connect T601, J723, and J731 of the
HV-DC PCB. Replace the HV-DC PCB.
E067
The high-voltage output has a fault.
0000
A fault is detected at the same time in 2 of the
following: primary high voltage, pre-transfer
high voltage, transfer high voltage, separation high
voltage.
Remove and mount the primary charging
assembly. Remove and mount the pre-
transfer
charging assembly. Remove and mount the
transfer/separation charging assembly.
Disconnect and then connect J721, J723,
J731, and J734 of the HV-DC PCB.
Replace the
HV-DC PCB. Replace the HV-AC PCB.
E068
The high-voltage output has a fault. (separation charging assembly)
0000
A fault (leak) has been detected while the separation
charging assembly is being supplied
with high voltage.
Remove and mount the transfer/separation
charging assembly. Disconnect and then
connect
J7233 and J734 of the HV-DC PCB.
Disconnect and then connect J741 and
J742 of the
HV-AC PCB. Replace the HV-AC PCB.
Replace the transfer/separation charging
assembly.
Replace the pre-transfer charging
assembly.
E069
The transfer high voltage has an error.
0000
A fault (leak) has been detected while the transfer
charging assembly is being supplied with
high voltage.
Remove and mount the transfer/separation
charging assembly. Check for soiling.
Disconnect and then connect T701 and
J723 of the HV-DC PCB. Replace the HV-
DC PCB.
Replace the pre-transfer charging
assembly.
E102
A read error has occurred in relation to the laser scanner unit EEPROM data.
Code
Description
Remedial action
*: model equipped with DADF-Q1 (outside Japan, iR7105/7095; inside Japan: iR7105/7095/7086).
**: model equipped with DADF-M1 (outside Japan: iR7086).
Содержание IMAGERUNNER 7095 PRINTER
Страница 20: ...Chapter 1 Introduction...
Страница 46: ...Chapter 2 Installation...
Страница 88: ...Chapter 3 Basic Operation...
Страница 94: ...Chapter 4 Main Controller...
Страница 116: ...Chapter 5 Original Exposure System...
Страница 165: ...Laser Exposure Chapter 6...
Страница 175: ...Chapter 7 Image Formation...
Страница 180: ...Chapter 7 7 3 7 3 Basic Sequence 7 3 1 Basic Sequence 0010 8038 F 7 3 ON ON WMUPR WMUP STBY OFF 100msec...
Страница 231: ...Chapter 8 Pickup Feeding System...
Страница 287: ...Chapter 9 Fixing System...
Страница 312: ...Chapter 10 External and Controls...
Страница 346: ...Chapter 11 MEAP...
Страница 350: ...Chapter 12 RDS...
Страница 360: ...Chapter 13 Maintenance Inspection...
Страница 375: ...Chapter 14 Standards Adjustments...
Страница 407: ...Chapter 15 Correcting Faulty Images...
Страница 433: ...Chapter 16 Self Diagnosis...
Страница 460: ...Chapter 17 Service Mode...
Страница 559: ...Chapter 18 Upgrading...
Страница 583: ...Chapter 19 Service Tools...
Страница 584: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 Special Tools Table 19 1 19 1 2 Solvents Oils 19 2...
Страница 588: ...APPENDIX...
Страница 615: ......