Chapter 16
16-13
0001
The version of the language file on the HDD and that
of bootable do not match.
Update the version of the language file
(Language), or install the appropriate file.
0002
The language file on the HDD is too large.
0003
There is no language to which a switchover is made as
described in the Config file on the
HDD.
0004
An attempt to switch over to the language described in
the Config file on the HDD fails.
1000
The connected boot ROM is not one designed for the
model in question.
Replace the boot ROM.
2000
An illegal engine ID has been detected.
Reinstall the system software.
E746
An unsupported optional board has been detected.
0003
The option board that has been detected is one deigned
for a different model.
Replace it with one for the model in
question.
E749
Restart in accordance with a change of the product configuration
0001
A boot ROM designed for a different model has been
fitted in place (as when installing
an PDL option).
There is no need for remedial action.
Nevertheless, the fact will remain as part of
the
error history.
E800
The auto power-off circuit has an error.
An open circuit has been detected for 3 sec or more in
the auto power-off circuit.
Turn off and then on the power. Disconnect
and then connect J505 of the DC controller
PCB.
Disconnect and then connect J1719 of the
relay PCB. Replace the relay PCB. Replace
the
DC controller PCB.
E804
The rotation of the following is faulty: power supply cooling fan 1, power supply cooling fan
2, controller cooling fan.
0001
The fan stop signal has been detected for 5 sec or more
after the power supply cooling fan 1
has gone on.
Disconnect and then connect J505 of the
DC controller PCB. Replace the power
supply
cooling fan 1. Replace the DC controller
PCB.
0002
The fan stop signal has been detected for 5 sec or more
after the power supply cooling fan 2
has gone on.
Disconnect and then connect J505 of the
DC controller PCB. Replace the power
supply
cooling fan 2. Replace the DC controller
PCB.
0004
The fan stop signal of the controller cooling fan has
been detected continuously for 16 sec.
Disconnect and then connect J1028 of the
main controller PCB. Replace the
controller
cooling fan. Replace the main controller
PCB.
E805
The fixing heat discharge fan rotation is faulty.
0002
The fan stop signal has been detected for 5 sec or more
after the fixing heat discharge fan
has gone on.
Disconnect and then connect J503 of the
DC controller PCB. Replace the fixing heat
discharge fan. Replace the DC controller
PCB.
E820
The drum fan rotation is faulty.
0000
The fan stop signal has been detected for 5 sec or more
after the drum fan has gone on.
Disconnect and then connect J512 of the
DC controller PCB. Replace the drum fan.
Replace the DC controller PCB.
E823
The pre-transfer charging assembly fan rotation is faulty.
Code
Description
Remedial action
*: model equipped with DADF-Q1 (outside Japan, iR7105/7095; inside Japan: iR7105/7095/7086).
**: model equipped with DADF-M1 (outside Japan: iR7086).
Содержание IMAGERUNNER 7095 PRINTER
Страница 20: ...Chapter 1 Introduction...
Страница 46: ...Chapter 2 Installation...
Страница 88: ...Chapter 3 Basic Operation...
Страница 94: ...Chapter 4 Main Controller...
Страница 116: ...Chapter 5 Original Exposure System...
Страница 165: ...Laser Exposure Chapter 6...
Страница 175: ...Chapter 7 Image Formation...
Страница 180: ...Chapter 7 7 3 7 3 Basic Sequence 7 3 1 Basic Sequence 0010 8038 F 7 3 ON ON WMUPR WMUP STBY OFF 100msec...
Страница 231: ...Chapter 8 Pickup Feeding System...
Страница 287: ...Chapter 9 Fixing System...
Страница 312: ...Chapter 10 External and Controls...
Страница 346: ...Chapter 11 MEAP...
Страница 350: ...Chapter 12 RDS...
Страница 360: ...Chapter 13 Maintenance Inspection...
Страница 375: ...Chapter 14 Standards Adjustments...
Страница 407: ...Chapter 15 Correcting Faulty Images...
Страница 433: ...Chapter 16 Self Diagnosis...
Страница 460: ...Chapter 17 Service Mode...
Страница 559: ...Chapter 18 Upgrading...
Страница 583: ...Chapter 19 Service Tools...
Страница 584: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 Special Tools Table 19 1 19 1 2 Solvents Oils 19 2...
Страница 588: ...APPENDIX...
Страница 615: ......