Chapter 5
5-2
5.1.2 Specifications, Controls, and Functions <iR7086>
0011-1804
The specifications, controls, and functions of the machine's original exposure system are as follows:
T-5-2
5.1.3 Major Components <iR7105/7095>
0010-7882
The major components of the original exposure system are as follows:
T-5-3
Item
Description
Scanning lamp
xenon lamp
Original scanning
book mode: by moving the scanner
ADF mode: by moving original
Original reading
resolution
600 x 600 dpi (main scanning x sub scanning)
Halftone
256 gradations
Scanning position
detection
by scanner HP sensor
lens
single-focal point, fixed type
Magnification
[1] in platen mode: 25% to 400%
main scanning direction: image processing by controller block
sub scanning direction: scanning speed variation (No. 1 mirror base;
100% or higher)
in combination with image processing by reader block (50% or higher
and lower than 100%)
in combination with image processing in reader block and controller
block (lower than 50%)
[2] ADF mode: 25% to 200%
main scanning direction: image processing in controller block
sub scanning direction: original movement speed variation (50% or
higher); in combination with image processing in controller block
(lower than 50%)
Scanner drive control No. 1/2 mirror base: control by pulse motor
Scanning lamp
control
[1]activation control by pulse motor
[2]error detection control
Original size
detection
[1]book mode
sub scanning direction: by reflection type sensor
main scanning direction: by CCD
[2] ADF mode
main scanning direction: by slide guide in ADF
sub scanning direction: by photosensor in ADF
Item
Notation
Description
Scanning lamp
LA1
xenon lamp (120,000 lx)
Scanner motor
M501
2-phase pulse motor (pulse control)
Reader Cooling fan 1
FM501
cools the reader block
Reader Cooling fan 2
FM502
cools the reader block
ADF open/closed sensor
PS501
detects the state (open/closed) of the ADF; at 25 deg
Scanner HP sensor
PS502
detects scanner home position
Original size sensor (AB)
---
detects the size in sub scanning direction (AB-configuration)
Original size sensor (inch)
---
detects size in sub scanning direction (inch)
Mirror
---
No. 1, 2, 3 mirrors
Inverter PCB
---
drives the scanning lamp
CCD unit
---
collects image data, performs analog image processing
Reader controller PCB
---
controls the reader unit as a whole, performs digital image processing
Содержание IMAGERUNNER 7095 PRINTER
Страница 20: ...Chapter 1 Introduction...
Страница 46: ...Chapter 2 Installation...
Страница 88: ...Chapter 3 Basic Operation...
Страница 94: ...Chapter 4 Main Controller...
Страница 116: ...Chapter 5 Original Exposure System...
Страница 165: ...Laser Exposure Chapter 6...
Страница 175: ...Chapter 7 Image Formation...
Страница 180: ...Chapter 7 7 3 7 3 Basic Sequence 7 3 1 Basic Sequence 0010 8038 F 7 3 ON ON WMUPR WMUP STBY OFF 100msec...
Страница 231: ...Chapter 8 Pickup Feeding System...
Страница 287: ...Chapter 9 Fixing System...
Страница 312: ...Chapter 10 External and Controls...
Страница 346: ...Chapter 11 MEAP...
Страница 350: ...Chapter 12 RDS...
Страница 360: ...Chapter 13 Maintenance Inspection...
Страница 375: ...Chapter 14 Standards Adjustments...
Страница 407: ...Chapter 15 Correcting Faulty Images...
Страница 433: ...Chapter 16 Self Diagnosis...
Страница 460: ...Chapter 17 Service Mode...
Страница 559: ...Chapter 18 Upgrading...
Страница 583: ...Chapter 19 Service Tools...
Страница 584: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 Special Tools Table 19 1 19 1 2 Solvents Oils 19 2...
Страница 588: ...APPENDIX...
Страница 615: ......