![Canon IMAGERUNNER 7095 PRINTER Скачать руководство пользователя страница 396](http://html1.mh-extra.com/html/canon/imagerunner-7095-printer/imagerunner-7095-printer_service-manual_4206532396.webp)
Chapter 14
14-19
3) Turn off and then on the power.
MEMO:
Execution of the following may delete the keys/
certificates used for encrypted communications
and the CA certificates used for authentication of
external server certificates:
- replacement/formatting of the HDD
- replacement of the main controller PCB/initial-
ization of the RAM
If a key/certificate for encrypted communications
has been deleted, the control panel screen will in-
dicate a message to the effect that the key has
been corrupted: however, the key/certificate/CA
certificate installed at time of shipment from the
factory may be
brought back by executing the following: COPI-
ER>FUNCTION>CLEAR>CA-KEY. If doing
so has failed, use the SST to install the key/certif-
icate/CA certificate, and execute CA-KEY once
again.
Points to Note When Executing Service Mode
Item CA-KEY
If the user has generated/added a key/certificate/
CA certificate on his/her own, executing CA-
KEY will also delete these files. Inform the user
of this, and ask him/her to re-install them as nec-
essary after the execution of CA-KEY.
Points to Note When Fitting the Security
Expansion Board
Whenever possible, do not replace the main con-
troller PCB as part of the troubleshooting work
conducted in relation to the installation of the se-
curity expansion board (option).
The machine checks the compatibility between
the HDD and the main controller PCB when a se-
curity expansion board is installed. Replacement
with a new board will cause the formatting of the
HDD to start automatically, thus deleting all user
data.
T-14-4
*1: limited to those settings that may be exported
using a remote UI or transmitted as part of
machine information.
*2: limited to when the MEAP application in
question offers a backup function.
*3: limited to data within the User Box.
When Replacing the Main Controller PCB
- Explain to the user that all user data will be de-
leted.
- As necessary, ask the user to make a backup of
those data items that permit making of a
backup.
- Explain to the user that the following data items
do not permit making of a backup, and require
remedial action:
<Suggestions for Remedial Action>
- for mode settings stored using the copy/Box
function, ask the user to newly enter the
settings.
- for read mode settings stored using the
transmission function, ask the user to newly
enter the settings.
- for files that are yet to be transmitted (i.e., files
for selected timer transmission or reserved for
transmission), ask the user to newly transmit
them.
- for registered forms used in image synthesis, ask
the user to newly enter them.
- for MEAP applications, ask the user to newly
install them.
- for MEAP SMS (service management services)
passwords, access the following: http://<iR IP
address>:8000/SMS.
(Use the factory
password
"MeapSmsLogin" (case-sensitive) to log in and
change the password.
- for job histories, if a record is needed, ask the
user to store away the history using a remote
UI. (However, there is no way of
returning the history to the HDD.)
- for key pairs and server certificates, if the user
has added any, ask for re-installation.
Data item deleted
Backup
possibility
address data registered in the address
book
Yes
settings made in user mode
Yes *1
settings stored in memory
Yes
license file for MEAP application
Yes
user authentication information stored
using SDL (simple device login)
Yes
data stored using MEAP application
Yes *2
mode memory stored using copy
function or Box function
No
data in Box
Yes *3
read mode settings stored using
transmission function
No
files yet to be read (those selected for
timer transmission or reserved for
transmission)
No
forms stored for image synthesis
No
MEAP application
No
password for MEAP SMS (service
management services); returns to
factory default
No
job history information
No
user authentication information stored
in relation to SSO (local device
authentication)
Yes
key pairs and server certificates stored
in conjunction with system control
settings
No
Data item deleted
Backup
possibility
Содержание IMAGERUNNER 7095 PRINTER
Страница 20: ...Chapter 1 Introduction...
Страница 46: ...Chapter 2 Installation...
Страница 88: ...Chapter 3 Basic Operation...
Страница 94: ...Chapter 4 Main Controller...
Страница 116: ...Chapter 5 Original Exposure System...
Страница 165: ...Laser Exposure Chapter 6...
Страница 175: ...Chapter 7 Image Formation...
Страница 180: ...Chapter 7 7 3 7 3 Basic Sequence 7 3 1 Basic Sequence 0010 8038 F 7 3 ON ON WMUPR WMUP STBY OFF 100msec...
Страница 231: ...Chapter 8 Pickup Feeding System...
Страница 287: ...Chapter 9 Fixing System...
Страница 312: ...Chapter 10 External and Controls...
Страница 346: ...Chapter 11 MEAP...
Страница 350: ...Chapter 12 RDS...
Страница 360: ...Chapter 13 Maintenance Inspection...
Страница 375: ...Chapter 14 Standards Adjustments...
Страница 407: ...Chapter 15 Correcting Faulty Images...
Страница 433: ...Chapter 16 Self Diagnosis...
Страница 460: ...Chapter 17 Service Mode...
Страница 559: ...Chapter 18 Upgrading...
Страница 583: ...Chapter 19 Service Tools...
Страница 584: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 Special Tools Table 19 1 19 1 2 Solvents Oils 19 2...
Страница 588: ...APPENDIX...
Страница 615: ......