App-2
IM 701210-06E
Appendix 1 Relationship between the Time Axis Setting, Sample Rate and Record Length
T/div
500ns
1
µ
s
2
µ
s
5
µ
s
10
µ
s
20
µ
s
50
µ
s
100
µ
s
200
µ
s
500
µ
s
1 ms
2 ms
5 ms
10 ms
20 ms
50 ms
100 ms
200 ms
500 ms
1 s
2 s
3 s
4 s
5 s
6 s
8 s
10 s
20 s
30 s
1 min
2 min
3 min
4 min
5 min
6 min
7 min
8 min
9 min
10 min
12 min
15 min
30 min
1 h
2 h
3 h
4 h
5 h
6 h
7 h
8 h
9 h
10 h
12 h
1 day
2 day
3 day
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
5 M
2 M
1 M
500 k
200 k
100 k
50 k
20 k
10 k
5 k
5 k
5 k
2 k
2 k
2 k
1 k
500
200
200
100
100
50
50
50
50
20
20
20
20
10
5
50
100
200
500
1 k
2 k
5 k
10 k
20 k
50 k
100 k
200 k
250 k
200 k
200 k
250 k
200 k
200 k
250 k
200 k
200 k
150 k
200 k
250 k
120 k
160 k
200 k
200 k
150 k
120 k
240 k
180 k
240 k
150 k
180 k
210 k
240 k
108 k
120 k
144 k
180 k
180 k
180 k
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
5 M
2 M
1 M
500 k
200 k
100 k
50 k
20 k
10 k
10 k
10 k
5 k
5 k
5 k
2 k
1 k
500
200
200
200
100
100
100
100
50
50
50
50
20
10
5
50
100
200
500
1 k
2 k
5 k
10 k
20 k
50 k
100 k
200 k
500 k
500 k
400 k
500 k
500 k
400 k
500 k
500 k
400 k
300 k
400 k
500 k
300 k
400 k
500 k
400 k
300 k
300 k
240 k
360 k
480 k
300 k
360 k
420 k
480 k
270 k
300 k
360 k
450 k
360 k
360 k
360 k
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
5 M
2 M
1 M
500 k
200 k
100 k
50 k
20 k
20 k
20 k
10 k
10 k
10 k
5 k
2 k
1 k
500
500
200
200
200
200
200
100
100
100
100
50
20
10
5
5
5
50
100
200
500
1 k
2 k
5 k
10 k
20 k
50 k
100 k
200 k
500 k
1 M
1 M
1 M
1 M
1 M
1 M
1 M
1 M
600 k
800 k
1 M
600 k
800 k
1 M
1 M
600 k
600 k
600 k
900 k
480 k
600 k
720 k
840 k
960 k
540 k
600 k
720 k
900 k
900 k
720 k
720 k
540 k
720 k
900 k
Record Length
250 kW
500 kW
1 MW
Sample
Rate
(S/s)
Sample
Rate
(S/s)
Display
Record
Length
(Word)
Display
Record
Length
(Word)
Display
Record
Length
(Word)
Sample
Rate
(S/s)
For the settings inside the thick frame, the waveform is displayed in roll mode when the trigger mode is set
to auto or auto-level.
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
5 M
2 M
1 M
500 k
200 k
100 k
50 k
20 k
10 k
5 k
2 k
1 k
1 k
1 k
500
500
500
200
100
50
20
20
20
10
10
10
10
5
5
5
5
50
100
200
500
1 k
2 k
5 k
10 k
20 k
50 k
50 k
40 k
50 k
50 k
40 k
50 k
50 k
40 k
50 k
50 k
40 k
30 k
40 k
50 k
30 k
40 k
50 k
40 k
30 k
30 k
24 k
36 k
48 k
30 k
36 k
42 k
48 k
27 k
30 k
36 k
45 k
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
5 M
2 M
1 M
500 k
200 k
100 k
50 k
20 k
10 k
5 k
2 k
2 k
2 k
1 k
1 k
1 k
500
200
100
50
50
20
20
20
20
20
10
10
10
10
5
50
100
200
500
1 k
2 k
5 k
10 k
20 k
50 k
100 k
100 k
100 k
100 k
100 k
100 k
100 k
100 k
100 k
100 k
100 k
60 k
80 k
100 k
60 k
80 k
100 k
100 k
60 k
60 k
60 k
90 k
48 k
60 k
72 k
84 k
96 k
54 k
60 k
72 k
90 k
90 k
50 kW
100 kW
Sample
Rate
(S/s)
Sample
Rate
(S/s)
Display
Record
Length
(Word)
Display
Record
Length
(Word)