![YOKOGAWA ScopeCorder DL750 User Manual Download Page 30](http://html.mh-extra.com/html/yokogawa/scopecorder-dl750/scopecorder-dl750_user-manual_911347030.webp)
10-14
IM 701210-06E
10.5 User-Defined Computation (Optional)
<For a description of this function, refer to page 2-48.>
Procedure
MEASURE CURSOR
RESET
SELECT
CH
ALL CH
MODE
POSITION
SIMPLE/ENHANCED
ACQ
START/STOP
SETUP
DISPLAY
ZOOM
DUAL
CAPTURE
HISTORY
MATH
1
CH
2
CH
3
CH
4
CH
5
CH
6
CH
7
CH
8
CH
9
CH
10
CH
11
CH
12
CH
13
CH
14
CH
15
CH
16
DELAY
MANUAL TRIG
V/DIV
TIME/DIV
TRIGGER
TRIG D
VERTICAL
HORIZONTAL
CAL
X-Y
SEARCH
7
DSP 1
8
9
DSP 2
6
5
4
1
0
2
3
ENTER
m
DSP 6
DSP 5
LOGIC A
LOGIC B
EVENT
DSP 3
DSP 4
EXP
GO/NO-GO
ACTION
FILE
SHIFT
1.
Press
MATH
.
2.
Press the
Mode
soft key and select ON to display Math waveforms, OFF to not
display them. If you select ON, proceed to step 3.
Setting the Computation Start and End Points
3.
Press the
Start Point/End Point
soft key to set the jog shuttle control to Start
Point.
4.
Turn the
jog shuttle
to set the computation start point.
5.
Likewise, set the End Point.
Setting the Computation
6.
Press the
Setup
soft key. The Math1 to Math8 setup dialog boxes appear.
7.
Use the
jog shuttle
and
SELECT
to select the Math waveform you wish to set.
A MathX setup dialog box opens.
Setting the Computing Operation
8.
Use the
jog shuttle
and
SELECT
to set Operation to UserDef( ).
User-Defined Equation
9.
Use the
jog shuttle
and
SELECT
to select UserDef( ). A menu for setting the
equation appears.
10.
Enter the equation using up to 55 characters according to the procedure given in
section 4.2. The head section (19 characters) of the entered equation is
displayed in the Expression box.
Use the jog shuttle and arrow keys
to select the desired operator.
To confirm, select ENT.
Select Math1 to Math8 and press
SELECT to enter the equation
displayed on the right side.
The contents entered from the
soft keyboard are displayed.