Operation
14. “UTILITY” mode
14.5 Changing the execution level
Program execution levels can be set as shown in the table below. However, the following
commands are usable only when return-to-origin is complete.
Movement commands
: MOVE, MOVE2, MOVEI, MOVEI2, DRIVE,
DRIVE2, DRIVEI, DRIVEI2, PMOVE, PMOVE2,
PATH START
Position acquisition command : WHERE, WHERE2, WHRXY, WHRXY2
LEVEL0
LEVEL1
LEVEL2
LEVEL3
LEVEL4
LEVEL5
LEVEL6
LEVEL7
LEVEL8
Disabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
MANUAL mode
MANUAL mode
MANUAL mode
AUTO mode
AUTO mode
MANUAL mode
AUTO mode
AUTO mode
AUTO mode
NO
NO
YES
NO
YES
YES
YES
NO
YES
NO
NO
NO
NO
NO
YES
YES
NO
YES
Invalid
Invalid
Invalid
Invalid
Invalid
Invalid
Invalid
Valid
(Note 1)
Valid
(Note 1)
Level
Program
execution at
origin incomplete
When power is turned on
Mode
Program reset
Return-to-origin
signal in AUTO
mode
Program reset
at program start
Description
Note 1: When the return-to-origin signal input (DI17) is valid in “AUTO” mode, the
robot program-in-progress signal (DO13) turns on during processing by the
return-to-origin signal input (DI17) in "AUTO" mode.
n
NOTE
Execution level is automatically set to
“LEVEL 0” in the following cases.
1. When parameter data was
damaged.
2. When system generation data was
damaged.
Summary of Contents for RCX141
Page 1: ...User s Manual ENGLISH E YAMAHA 4 AXIS ROBOT CONTROLLER E93 Ver 2 02 RCX141 ...
Page 2: ......
Page 16: ...viii MEMO ...
Page 18: ...MEMO ...
Page 24: ...1 6 MEMO ...
Page 26: ...MEMO ...
Page 34: ...2 8 MEMO ...
Page 36: ...MEMO ...
Page 54: ...3 18 MEMO ...
Page 290: ...4 232 MEMO ...
Page 292: ...MEMO ...
Page 316: ...5 24 MEMO ...
Page 318: ...MEMO ...
Page 326: ...6 8 MEMO ...
Page 328: ...MEMO ...
Page 338: ...7 10 MEMO ...
Page 340: ...MEMO ...
Page 346: ...MEMO ...
Page 401: ...MEMO ...