4-
186
Operation
4
12. “SYSTEM” mode
n
NOTE
Data omissions may occur if data flow
control is not performed. Make use of
data flow control as much as possible.
8. RTS/CTS control
This parameter sets whether to control the data flow using RTS/CTS signal.
[Procedure]
1) Select “8. RTS/CTS CONTROL> in “SYSTEM>CMU “ mode.
2) Press the
F 1
(EDIT) key.
The function key menu changes.
Fig. 4-12-62 “RTS/CTS CONTROL” setting
SYSTEM
>CMU V8.30
4.Stop bit
1
5.Parity
ODD
6.Termination
code
CRLF
7.XON/XOFF control YES
8.RTS/CTS control
YES
YES
NO
3) Select the
F 1
(YES) or
F 2
(NO) key.
4) Press the
ESC
key to quit the edit mode.