4-
213
4
Operation
12. “SYSTEM” mode
12.5.2
Error history display
To display past errors that occurred, follow the procedure below. A maximum of 500
items may be stored in the error history.
[Procedure]
1) Press the
F 2
(HISTRY) key to enter “SYSTEM>DIAGNOS> HISTRY” mode.
Fig. 4-12-99 Error history
SYSTEM
>DIAGNOS>HISTRY V8.30
1:04/05/01,10:15:00 12.1:Emg.stop on
2:04/05/01,10:14:54 22.1:AC power low
3:04/05/01,09:59:34 17.4:D1,Over load
4:04/04/28,14:00:02 12.1:Emg.stop on
5:04/03/31,08:40:10 22.1:AC power low
NEXT P. PREV.P.
CLEAR
One screen displays the past 5 errors in order from the most recent error.
Error information is displayed in the following format.
<Date>, <Time> <Error No.>:<Error message>
* The hour, minute and second are displayed for the time.
2) Check the error history.
Pressing the cursor (
↑
/
↓
) keys changes the display one line at a time.
Pressing the
F 1
(NEXT P.) or
F 2
(PREV. P.) key changes the display one
screen at a time.
3) Press the
F 5
key if you want to clear the error history.
4) Press the
ESC
key to return to “SYSTEM>DIAGNOS” mode.
c
CAUTION
• Errors are not recorded when
identical to a preceding error that
just occurred.
• The error category “0” is not
recorded.
• The error history is initialized
when the
F 5
(CLEAR) key is
used. Do not initialize if you want
to retain the error history.
Summary of Contents for RCX141
Page 1: ...User s Manual ENGLISH E YAMAHA 4 AXIS ROBOT CONTROLLER E93 Ver 2 02 RCX141 ...
Page 2: ......
Page 16: ...viii MEMO ...
Page 18: ...MEMO ...
Page 24: ...1 6 MEMO ...
Page 26: ...MEMO ...
Page 34: ...2 8 MEMO ...
Page 36: ...MEMO ...
Page 54: ...3 18 MEMO ...
Page 290: ...4 232 MEMO ...
Page 292: ...MEMO ...
Page 316: ...5 24 MEMO ...
Page 318: ...MEMO ...
Page 326: ...6 8 MEMO ...
Page 328: ...MEMO ...
Page 338: ...7 10 MEMO ...
Page 340: ...MEMO ...
Page 346: ...MEMO ...
Page 401: ...MEMO ...