4-
178
Operation
4
12. “SYSTEM” mode
2) Select the parameter with the cursor (
↑
/
↓
) keys.
Fig. 4-12-49
SYSTEM
>PARAM>OP.BRD>SELECT
V8.63
1.board condition
VALID
2.remote cmd / IO cmd(SI05)
VALID
3.Output MSG to SOW(1)
INVALID
EDIT
JUMP
4.IO size
Large
3) Press the
F 1
(EDIT) key.
Fig. 4-12-50
SYSTEM
>PARAM>OP.BRD>SELECT
V8.63
1.board condition
VALID
2.remote cmd / IO cmd(SI05)
VALID
3.Output MSG to SOW(1)
INVALID
INVALID
VALID
4.IO size
Large
4) Press the
F 1
(INVALID) or
F 2
(VALID) key.
To select “4. IO size”, press the
F 1
(Large) or
F 2
(Small) key.
5) Press the
ESC
key to quit the edit mode.
Summary of Contents for RCX141
Page 1: ...User s Manual ENGLISH E YAMAHA 4 AXIS ROBOT CONTROLLER E93 Ver 2 02 RCX141 ...
Page 2: ......
Page 16: ...viii MEMO ...
Page 18: ...MEMO ...
Page 24: ...1 6 MEMO ...
Page 26: ...MEMO ...
Page 34: ...2 8 MEMO ...
Page 36: ...MEMO ...
Page 54: ...3 18 MEMO ...
Page 290: ...4 232 MEMO ...
Page 292: ...MEMO ...
Page 316: ...5 24 MEMO ...
Page 318: ...MEMO ...
Page 326: ...6 8 MEMO ...
Page 328: ...MEMO ...
Page 338: ...7 10 MEMO ...
Page 340: ...MEMO ...
Page 346: ...MEMO ...
Page 401: ...MEMO ...