e-STUDIO200L/202L/230/232/280/282 TROUBLESHOOTING
June 2004 © TOSHIBA TEC
5 - 46
[ 5 ] Other paper jam
[EAD0] Print end command time-out jam
Is the main motor rotating normally?
#
NO
1) Replace the SYS board.
2) Replace the LGC board.
[EAE0]
Receiving time time-out jam
Is the finisher working?
#
YES
Replace the finisher controller PC board.
NO
1) Check if the voltage (24V) is being supplied to the finisher.
2) Check the connection of the LGC board and IPC board.
3) Check if the harness connecting the IPC board and finisher I/F connector of the equip-
ment side is open circuited.
4) Check if the harness connecting the I/F connector of the finisher side and finisher con-
troller PC board is open circuited.
5) Replace the finisher controller PC board.
[EB30]
Ready time time-out jam
Is there paper in the equipment?
#
NO
Replace the LGC board.
YES
Are the IPC board and LGC board properly connected to each other?
#
NO
Connect them properly.
YES
Is the harness securely connected to the IPC board?
#
NO
Connect the harness properly.
YES
Is any of the connector pins of the harness connecting the equipment and finisher discon-
nected or any of those harnesses open circuited?
#
NO
Connect the pin or replace the harness.
YES
1) Replace the IPC board.
2) Replace the LGC board.
3) Replace the finisher controller PC board.
Summary of Contents for e-STUDIO200L
Page 6: ......
Page 12: ......
Page 400: ...e STUDIO200L 202L 230 232 280 282 ADJUSTMENT June 2004 TOSHIBA TEC 3 104 ...
Page 554: ...e STUDIO200L 202L 230 232 280 282 TROUBLESHOOTING June 2004 TOSHIBA TEC 5 124 ...
Page 678: ...e STUDIO200L 202L 230 232 280 282 REMOTE SERVICE June 2004 TOSHIBA TEC 8 24 ...
Page 702: ...e STUDIO200L 202L 230 232 280 282 WIRE HARNESS CONNECTION DIAGRAMS June 2004 TOSHIBA TEC 10 2 ...
Page 707: ......
Page 708: ......