5
4) Toner offset
Fig. 5-4
Toner offset (Shadow image appears approx. 94 mm toward the dark image.)
Defective area
Step
Check items
Prescription
Density
1
Is the density too high?
Adjust the density.
Fuser unit
2
Is the pressure of the fuser roller nor-
mal?
Check the pressure releasing parts
and pressurization mechanism.
3
Is the thermistor in contact with the
fuser roller?
Contact the thermistor with the fuser
roller.
4
Is there a scratch on the fuser roller
surface?
Replace the fuser roller.
5
Has the fuser roller reached its PM
life?
Replace the fuser roller.
6
Is the setting temperature of the fuser
roller normal?
Check the adjustment values of fuser
roller temperature?
08-407, 410, 411, 450, 515, 516
Paper
7
Has the appropriate paper type been
selected?
Select a proper mode.
8
Is the setting temperature of the fuser
roller in each paper type normal?
Check the setting and correct it.
08-412, 413, 437, 438, 451, 452,
453, 518, 520, 521
9
Using the recommended paper?
Use the recommended paper.
Developer material
10
Using the specified developer mate-
rial?
Use the specified developer material
and toner.
Scanner
11
Are the original glass (especially the
position of shading correction plate),
mirror and lens dirty?
Clean them.
Feeding direction
Approx.94mm
Summary of Contents for e-STUDIO200L
Page 6: ......
Page 12: ......
Page 400: ...e STUDIO200L 202L 230 232 280 282 ADJUSTMENT June 2004 TOSHIBA TEC 3 104 ...
Page 554: ...e STUDIO200L 202L 230 232 280 282 TROUBLESHOOTING June 2004 TOSHIBA TEC 5 124 ...
Page 678: ...e STUDIO200L 202L 230 232 280 282 REMOTE SERVICE June 2004 TOSHIBA TEC 8 24 ...
Page 702: ...e STUDIO200L 202L 230 232 280 282 WIRE HARNESS CONNECTION DIAGRAMS June 2004 TOSHIBA TEC 10 2 ...
Page 707: ......
Page 708: ......