C940
Circuit related ser-
vice call
Engine-CPU abnormality
P. 5-76
C970
Process related
service call
High-voltage transformer abnormality: Leakage of the
main charger is detected.
P. 5-76
CA10
Laser optical unit
related service call
Polygonal motor abnormality: The polygonal motor is not
rotating normally.
P. 5-60
CA20
H-Sync detection error: H-Sync detection PC board can-
not detect laser beams.
P. 5-60
CB10
Finisher related
service call
Transport motor abnormality: The transport motor or
stack transport roller is not rotating normally. [MJ-1025]
P. 5-61
CB20
Delivery motor abnormality: Delivery motor or delivery
roller is not rotating normally. [MJ-1022/1025]
P. 5-62
CB30
Tray lift motor abnormality: The tray lift motor is not rotat-
ing normally or the delivery tray is not moving normally.
[MJ-1025]
P. 5-63
CB50
Staple motor (staple/fold) abnormality: The staple motor
is not rotating normally or the stapler is not moving nor-
mally. [MJ-1025]
P. 5-64
CB60
Stapler unit shift motor abnormality: The stapler unit shift
motor is not rotating normally or the Stapler Unit is not
moving normally. [MJ-1025]
P. 5-66
CB80
Backup RAM data abnormality:
1) Abnormality of checksum value on finisher controller
board is detected when the power is turned on.
[MJ-1025]
2) Abnormality of checksum value on punch controller
board is detected when the power is turned on.
[MJ-1025 (when MJ-6005 is installed)]
P. 5-67
CC30
Stack processing motor abnormality: The stack process-
ing motor is not rotating normally or the stack delivery belt
is not moving normally. [MJ-1022]
Paddle motor abnormality: The paddle motor is not rotat-
ing normally or the swing guide is not moving normally.
[MJ-1025]
P. 5-67
CC50
Horizontal registration motor abnormality: The horizontal
registration motor is not rotating normally or the puncher
is not moving normally.
[MJ-1025 (when MJ-6005 is installed)]
P. 5-69
CC60
Punch motor abnormality: The punch motor is not rotating
normally or the puncher is not moving normally.
[MJ-1025 (when MJ-6005 is installed)]
P. 5-69
CC80
Front jogging motor abnormality: Front jogging motor is
not rotating normally or the front alignment plate is not
moving normally. [MJ-1022]
Alignment motor (front) abnormality: The alignment motor
(front) is not rotating normally or the front alignment plate
is not moving normally. [MJ-1025]
P. 5-70
CC90
Upper stack tray lift motor abnormality: The upper stack
tray lift motor is not rotating or the upper stack tray is not
moving normally. [MJ-1022]
P. 5-71
CCA0
Lower stack tray lift motor abnormality: The lower stack
tray lift motor is not rotating or the lower stack tray is not
moving normally. [MJ-1022]
P. 5-72
CCB0
Rear jogging motor abnormality: Rear jogging motor is
not rotating normally or the rear alignment plate is not
moving normally. [MJ-1022]
Alignment motor (rear) abnormality: The alignment motor
(rear) is not rotating normally or the rear alignment plate
is not moving normally. [MJ-1025]
P. 5-73
Error code
Classification
Contents
Troubleshooting
Summary of Contents for e-STUDIO200L
Page 6: ......
Page 12: ......
Page 400: ...e STUDIO200L 202L 230 232 280 282 ADJUSTMENT June 2004 TOSHIBA TEC 3 104 ...
Page 554: ...e STUDIO200L 202L 230 232 280 282 TROUBLESHOOTING June 2004 TOSHIBA TEC 5 124 ...
Page 678: ...e STUDIO200L 202L 230 232 280 282 REMOTE SERVICE June 2004 TOSHIBA TEC 8 24 ...
Page 702: ...e STUDIO200L 202L 230 232 280 282 WIRE HARNESS CONNECTION DIAGRAMS June 2004 TOSHIBA TEC 10 2 ...
Page 707: ......
Page 708: ......