June 2004 © TOSHIBA TEC
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 101
3
3.15 Adjustment of Dogleg
Dogleg is the name given to an image which is deformed approx. 48 mm of the trailing edge of the out-
put paper.
Since adjustment has usually been performed when the equipment was manufactured, dogleg image
should not occur. However, if the following dogleg image A or B does happen to occur, the following
adjustment must be performed. An original with a line parallel to the feeding direction is used for the
adjustment.
Fig.3-138
Fig.3-139
Fig.3-140
Normal Image
Feeding
Direction
Feeding
Direction
Dogleg Image A
Approx. 48 mm of
the trailing edge
Dogleg Image B
Feeding
Direction
Approx. 48 mm of
the trailing edge
06/01
Summary of Contents for e-STUDIO200L
Page 6: ......
Page 12: ......
Page 400: ...e STUDIO200L 202L 230 232 280 282 ADJUSTMENT June 2004 TOSHIBA TEC 3 104 ...
Page 554: ...e STUDIO200L 202L 230 232 280 282 TROUBLESHOOTING June 2004 TOSHIBA TEC 5 124 ...
Page 678: ...e STUDIO200L 202L 230 232 280 282 REMOTE SERVICE June 2004 TOSHIBA TEC 8 24 ...
Page 702: ...e STUDIO200L 202L 230 232 280 282 WIRE HARNESS CONNECTION DIAGRAMS June 2004 TOSHIBA TEC 10 2 ...
Page 707: ......
Page 708: ......