e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
June 2004 © TOSHIBA TEC
2 - 14
5) File sharing related error
(when GM-1020/3020, 1030/3030, 2020 or 2030 is installed (e-STUDIO200L/230/280))
(when GM-1070/4070, 1080U/4080U, 2070 or 2080U is installed (e-STUDIO202L/232/282))
Error code
Message displayed in the
TopAccess screen
Contents
Troubleshooting
2D10
Illegal Job status
System access abnormality
P. 5-88
2D11
Not enough memory
Insufficient memory
P. 5-88
2D12
Illegal Job status
Message reception error
P. 5-88
2D13
Illegal Job status
Message transmission error
P. 5-88
2D14
Invalid parameter specified
Invalid parameter
P. 5-88
2D15
There are too many documents in
the folder. Failed in creating new
document.
Exceeding document number
P. 5-88
2D20
Illegal Job status
System management module access
abnormality
P. 5-88
2D21
Illegal Job status
Job control module access abnormality
P. 5-88
2D22
Illegal Job status
Job control module access abnormality
P. 5-88
2D30
Failed to create directory
Directory creation failure
P. 5-88
2D31
Failed to create file
File creation failure
P. 5-88
2D32
Failed to delete file
File deletion failure
P. 5-88
2D33
Failed to create file
File access failure
P. 5-88
2D40
Failed to convert image file for-
mat
Image conversion abnormality
P. 5-89
2D60
Failed to copy file
File library access abnormality
P. 5-88
2D61
Invalid parameter specified
Invalid parameter
P. 5-88
2D62
Failed to connect to network des-
tination. Check destination path
File server connection error
P. 5-89
2D63
Specified network path is invalid.
Check destination path
Invalid network path
P. 5-89
2D64
Logon to file server failed. Check
username and password
Login failure
P. 5-89
2D65
There are too many documents in
the folder. Failed in creating new
document.
Exceeding documents in folder: Creating
new document is failed.
P. 5-89
2D66
Failed to process your Job. Insuf-
ficient disk space.
HDD full failure during processing
P. 5-89
2D67
FTP service is not available
FTP service not available
P. 5-89
2D68
File Sharing service is not avail-
able
File sharing service not available
P. 5-89
2DA0
Expired scan documents deleted
from share folder.
Periodical deletion of scanned docu-
ments completed properly.
-
2DA1
Expired Sent Fax documents
deleted from shared folder.
Periodical deletion of transmitted FAX
documents completed properly.
-
2DA2
Expired Received Fax documents
deleted from shared folder.
Periodical deletion of received FAX doc-
uments completed properly.
-
2DA3
Scanned documents in shared
folder deleted upon user's
request.
Manual deletion of scanned documents
completed properly.
-
2DA4
Sent Fax Documents in shared
folder deleted upon user's
request.
Manual deletion of transmitted FAX doc-
uments completed properly.
-
2DA5
Received Fax Documents in
shared folder deleted upon user's
request.
Manual deletion of received FAX docu-
ments completed properly.
-
2DA6
Failed to delete file.
File deletion failure
P. 5-88
05/11
Summary of Contents for e-STUDIO200L
Page 6: ......
Page 12: ......
Page 400: ...e STUDIO200L 202L 230 232 280 282 ADJUSTMENT June 2004 TOSHIBA TEC 3 104 ...
Page 554: ...e STUDIO200L 202L 230 232 280 282 TROUBLESHOOTING June 2004 TOSHIBA TEC 5 124 ...
Page 678: ...e STUDIO200L 202L 230 232 280 282 REMOTE SERVICE June 2004 TOSHIBA TEC 8 24 ...
Page 702: ...e STUDIO200L 202L 230 232 280 282 WIRE HARNESS CONNECTION DIAGRAMS June 2004 TOSHIBA TEC 10 2 ...
Page 707: ......
Page 708: ......